{"product_id":"biobase-vertical-pressure-steam-autoclave-35l-50l-75l-100l","title":"BIOBASE BKQ-BV Class B Vertical Pulse Vacuum Steam Autoclave (50L, 75L \u0026 100L)","description":"\u003cp data-start=\"625\" data-end=\"906\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"629\" data-end=\"686\"\u003eBIOBASE Class B Vertical Pulse Vacuum Steam Autoclave\u003c\/strong\u003e is a premium laboratory steriliser designed for research laboratories, universities, pharmaceutical facilities, biotechnology laboratories and quality control environments requiring advanced Class B steam sterilisation.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"908\" data-end=\"1350\"\u003eAvailable in \u003cstrong data-start=\"921\" data-end=\"942\"\u003e50L, 75L and 100L\u003c\/strong\u003e capacities, the BKQ-BV Series uses an advanced pulse vacuum system that repeatedly evacuates air from the chamber before introducing saturated steam. This provides superior steam penetration for wrapped instruments, unwrapped instruments, dressings, rubber items, laboratory glassware, culture media and non-enclosed liquids, delivering reliable sterilisation across a wide range of laboratory applications.\u003c\/p\u003e\n\u003cp data-start=\"1352\" data-end=\"1805\"\u003eDesigned for demanding laboratory environments, the BKQ-BV Series completes the entire sterilisation cycle automatically, including preheating, pulse vacuum, heating, sterilisation and vacuum drying. A built-in thermal printer, liquid temperature probe, high-efficiency sterile air filter and closed steam-water circulation system provide complete cycle documentation, excellent sterilisation performance and reduced steam discharge into the laboratory.\u003c\/p\u003e\n\u003chr data-start=\"1807\" data-end=\"1810\"\u003e\n\u003ch1 data-section-id=\"1h67pi1\" data-start=\"1812\" data-end=\"1825\"\u003eFeatures\u003c\/h1\u003e\n\u003cul data-start=\"1827\" data-end=\"2773\"\u003e\n\u003cli data-section-id=\"kk0wnb\" data-start=\"1827\" data-end=\"1872\"\u003eEuropean Class B pulse vacuum sterilisation\u003c\/li\u003e\n\u003cli data-section-id=\"hbz4ft\" data-start=\"1873\" data-end=\"1920\"\u003eAvailable in \u003cstrong data-start=\"1888\" data-end=\"1909\"\u003e50L, 75L and 100L\u003c\/strong\u003e capacities\u003c\/li\u003e\n\u003cli data-section-id=\"1t1km2n\" data-start=\"1921\" data-end=\"1954\"\u003ePulse vacuum air removal system\u003c\/li\u003e\n\u003cli data-section-id=\"19he5k3\" data-start=\"1955\" data-end=\"1980\"\u003eAutomatic vacuum drying\u003c\/li\u003e\n\u003cli data-section-id=\"1q69xkk\" data-start=\"1981\" data-end=\"2022\"\u003eClosed steam-water internal circulation\u003c\/li\u003e\n\u003cli data-section-id=\"b50wxf\" data-start=\"2023\" data-end=\"2060\"\u003eBuilt-in thermal printer (standard)\u003c\/li\u003e\n\u003cli data-section-id=\"1fz3z50\" data-start=\"2061\" data-end=\"2080\"\u003eLarge LCD display\u003c\/li\u003e\n\u003cli data-section-id=\"1xt1glq\" data-start=\"2081\" data-end=\"2149\"\u003eReal-time pressure, temperature, time and operating status display\u003c\/li\u003e\n\u003cli data-section-id=\"858lez\" data-start=\"2150\" data-end=\"2201\"\u003eMobile temperature probe for liquid sterilisation\u003c\/li\u003e\n\u003cli data-section-id=\"zh84zd\" data-start=\"2202\" data-end=\"2246\"\u003e0.22 μm high-efficiency sterile air filter\u003c\/li\u003e\n\u003cli data-section-id=\"1rfx4mi\" data-start=\"2247\" data-end=\"2269\"\u003eAutomatic preheating\u003c\/li\u003e\n\u003cli data-section-id=\"10db0fg\" data-start=\"2270\" data-end=\"2295\"\u003eAutomatic pulse exhaust\u003c\/li\u003e\n\u003cli data-section-id=\"1qx3du5\" data-start=\"2296\" data-end=\"2315\"\u003eAutomatic heating\u003c\/li\u003e\n\u003cli data-section-id=\"h5lep3\" data-start=\"2316\" data-end=\"2341\"\u003eAutomatic sterilisation\u003c\/li\u003e\n\u003cli data-section-id=\"1ml39i2\" data-start=\"2342\" data-end=\"2360\"\u003eAutomatic drying\u003c\/li\u003e\n\u003cli data-section-id=\"1efhp4c\" data-start=\"2361\" data-end=\"2389\"\u003eWrapped instrument program\u003c\/li\u003e\n\u003cli data-section-id=\"13hcfbr\" data-start=\"2390\" data-end=\"2420\"\u003eUnwrapped instrument program\u003c\/li\u003e\n\u003cli data-section-id=\"t28jdb\" data-start=\"2421\" data-end=\"2439\"\u003eDressing program\u003c\/li\u003e\n\u003cli data-section-id=\"31fr70\" data-start=\"2440\" data-end=\"2456\"\u003eRubber program\u003c\/li\u003e\n\u003cli data-section-id=\"1kv9hmq\" data-start=\"2457\" data-end=\"2487\"\u003eLiquid sterilisation program\u003c\/li\u003e\n\u003cli data-section-id=\"1le8szn\" data-start=\"2488\" data-end=\"2511\"\u003eLiquid custom program\u003c\/li\u003e\n\u003cli data-section-id=\"1xj89oy\" data-start=\"2512\" data-end=\"2534\"\u003eSolid custom program\u003c\/li\u003e\n\u003cli data-section-id=\"1i6dmxf\" data-start=\"2535\" data-end=\"2565\"\u003eMedium sterilisation program\u003c\/li\u003e\n\u003cli data-section-id=\"1i6vq06\" data-start=\"2566\" data-end=\"2594\"\u003eMedium dissolution program\u003c\/li\u003e\n\u003cli data-section-id=\"1j6i6ln\" data-start=\"2595\" data-end=\"2614\"\u003eBowie \u0026amp; Dick test\u003c\/li\u003e\n\u003cli data-section-id=\"1i8gqas\" data-start=\"2615\" data-end=\"2633\"\u003eVacuum leak test\u003c\/li\u003e\n\u003cli data-section-id=\"1dsaqjd\" data-start=\"2634\" data-end=\"2659\"\u003eStainless steel chamber\u003c\/li\u003e\n\u003cli data-section-id=\"8oc9au\" data-start=\"2660\" data-end=\"2697\"\u003eMicroprocessor-controlled operation\u003c\/li\u003e\n\u003cli data-section-id=\"1fkuln0\" data-start=\"2698\" data-end=\"2744\"\u003eMultiple automatic safety protection systems\u003c\/li\u003e\n\u003cli data-section-id=\"ur2hz8\" data-start=\"2745\" data-end=\"2773\"\u003e240V Australian compatible\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2775\" data-end=\"2778\"\u003e\n\u003ch1 data-section-id=\"1lf6p35\" data-start=\"2780\" data-end=\"2794\"\u003eIdeal For\u003c\/h1\u003e\n\u003cul data-start=\"2796\" data-end=\"3051\"\u003e\n\u003cli data-section-id=\"knhpoo\" data-start=\"2796\" data-end=\"2819\"\u003eMycology laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"tuv45w\" data-start=\"2820\" data-end=\"2843\"\u003eResearch laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"10gwr6y\" data-start=\"2844\" data-end=\"2858\"\u003eUniversities\u003c\/li\u003e\n\u003cli data-section-id=\"60wbl6\" data-start=\"2859\" data-end=\"2888\"\u003ePharmaceutical laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1or0uhb\" data-start=\"2889\" data-end=\"2917\"\u003eBiotechnology laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"l94mk0\" data-start=\"2918\" data-end=\"2943\"\u003eVeterinary laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1pcjfkp\" data-start=\"2944\" data-end=\"2971\"\u003eFood testing laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"14jhzbb\" data-start=\"2972\" data-end=\"3002\"\u003eQuality control laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"10vtoei\" data-start=\"3003\" data-end=\"3028\"\u003eIndustrial laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"qg6mxy\" data-start=\"3029\" data-end=\"3051\"\u003eMedical laboratories\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3053\" data-end=\"3056\"\u003e\n\u003ch1 data-section-id=\"1qk0eh9\" data-start=\"3058\" data-end=\"3081\"\u003eAvailable Variants\u003c\/h1\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3083\" data-end=\"3226\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3083\" data-end=\"3103\"\u003e\n\u003ctr data-start=\"3083\" data-end=\"3103\"\u003e\n\u003cth data-start=\"3083\" data-end=\"3091\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eModel\u003c\/th\u003e\n\u003cth data-start=\"3091\" data-end=\"3103\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eCapacity\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3126\" data-end=\"3226\"\u003e\n\u003ctr data-start=\"3126\" data-end=\"3158\"\u003e\n\u003ctd data-start=\"3126\" data-end=\"3141\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3128\" data-end=\"3140\"\u003eBKQ-B50V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3141\" data-end=\"3158\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3143\" data-end=\"3156\"\u003e50 Litres\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3159\" data-end=\"3191\"\u003e\n\u003ctd data-start=\"3159\" data-end=\"3174\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3161\" data-end=\"3173\"\u003eBKQ-B75V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3174\" data-end=\"3191\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3176\" data-end=\"3189\"\u003e75 Litres\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3192\" data-end=\"3226\"\u003e\n\u003ctd data-start=\"3192\" data-end=\"3208\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3194\" data-end=\"3207\"\u003eBKQ-B100V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3208\" data-end=\"3226\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3210\" data-end=\"3224\"\u003e100 Litres\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"3228\" data-end=\"3231\"\u003e\n\u003ch1 data-section-id=\"g1cszw\" data-start=\"3233\" data-end=\"3262\"\u003eTechnical Specifications\u003c\/h1\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3264\" data-end=\"4160\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3264\" data-end=\"3315\"\u003e\n\u003ctr data-start=\"3264\" data-end=\"3315\"\u003e\n\u003cth data-start=\"3264\" data-end=\"3280\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"3280\" data-end=\"3291\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eBKQ-B50V\u003c\/th\u003e\n\u003cth data-start=\"3291\" data-end=\"3302\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eBKQ-B75V\u003c\/th\u003e\n\u003cth data-start=\"3302\" data-end=\"3315\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eBKQ-B100V\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3367\" data-end=\"4160\"\u003e\n\u003ctr data-start=\"3367\" data-end=\"3420\"\u003e\n\u003ctd data-start=\"3367\" data-end=\"3389\" data-col-size=\"sm\"\u003eSterilisation Class\u003c\/td\u003e\n\u003ctd data-start=\"3389\" data-end=\"3399\" data-col-size=\"sm\"\u003eClass B\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3399\" data-end=\"3409\"\u003eClass B\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3409\" data-end=\"3420\"\u003eClass B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3421\" data-end=\"3470\"\u003e\n\u003ctd data-start=\"3421\" data-end=\"3432\" data-col-size=\"sm\"\u003eCapacity\u003c\/td\u003e\n\u003ctd data-start=\"3432\" data-end=\"3444\" data-col-size=\"sm\"\u003e50 Litres\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3444\" data-end=\"3456\"\u003e75 Litres\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3456\" data-end=\"3470\"\u003e100 Litres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3471\" data-end=\"3558\"\u003e\n\u003ctd data-start=\"3471\" data-end=\"3494\" data-col-size=\"sm\"\u003eSterilisation Method\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3494\" data-end=\"3515\"\u003ePulse Vacuum Steam\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3515\" data-end=\"3536\"\u003ePulse Vacuum Steam\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3536\" data-end=\"3558\"\u003ePulse Vacuum Steam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3559\" data-end=\"3654\"\u003e\n\u003ctd data-start=\"3559\" data-end=\"3578\" data-col-size=\"sm\"\u003eChamber Material\u003c\/td\u003e\n\u003ctd data-start=\"3578\" data-end=\"3603\" data-col-size=\"sm\"\u003eS30408 Stainless Steel\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3603\" data-end=\"3628\"\u003eS30408 Stainless Steel\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3628\" data-end=\"3654\"\u003eS30408 Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3655\" data-end=\"3690\"\u003e\n\u003ctd data-start=\"3655\" data-end=\"3671\" data-col-size=\"sm\"\u003eVacuum Drying\u003c\/td\u003e\n\u003ctd data-start=\"3671\" data-end=\"3677\" data-col-size=\"sm\"\u003eYes\u003c\/td\u003e\n\u003ctd data-start=\"3677\" data-end=\"3683\" data-col-size=\"sm\"\u003eYes\u003c\/td\u003e\n\u003ctd data-start=\"3683\" data-end=\"3690\" data-col-size=\"sm\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3691\" data-end=\"3735\"\u003e\n\u003ctd data-start=\"3691\" data-end=\"3701\" data-col-size=\"sm\"\u003ePrinter\u003c\/td\u003e\n\u003ctd data-start=\"3701\" data-end=\"3712\" data-col-size=\"sm\"\u003eStandard\u003c\/td\u003e\n\u003ctd data-start=\"3712\" data-end=\"3723\" data-col-size=\"sm\"\u003eStandard\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3723\" data-end=\"3735\"\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3736\" data-end=\"3797\"\u003e\n\u003ctd data-start=\"3736\" data-end=\"3763\" data-col-size=\"sm\"\u003eLiquid Temperature Probe\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3763\" data-end=\"3774\"\u003eStandard\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3774\" data-end=\"3785\"\u003eStandard\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3785\" data-end=\"3797\"\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3798\" data-end=\"3887\"\u003e\n\u003ctd data-start=\"3798\" data-end=\"3811\" data-col-size=\"sm\"\u003eAir Filter\u003c\/td\u003e\n\u003ctd data-start=\"3811\" data-end=\"3836\" data-col-size=\"sm\"\u003e0.22 μm Sterile Filter\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3836\" data-end=\"3861\"\u003e0.22 μm Sterile Filter\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3861\" data-end=\"3887\"\u003e0.22 μm Sterile Filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3888\" data-end=\"3947\"\u003e\n\u003ctd data-start=\"3888\" data-end=\"3910\" data-col-size=\"sm\"\u003eWorking Temperature\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3910\" data-end=\"3922\"\u003e105–134°C\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3922\" data-end=\"3934\"\u003e105–134°C\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3934\" data-end=\"3947\"\u003e105–134°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3948\" data-end=\"4001\"\u003e\n\u003ctd data-start=\"3948\" data-end=\"3967\" data-col-size=\"sm\"\u003eWorking Pressure\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3967\" data-end=\"3978\"\u003e0.23 MPa\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3978\" data-end=\"3989\"\u003e0.23 MPa\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3989\" data-end=\"4001\"\u003e0.23 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4002\" data-end=\"4031\"\u003e\n\u003ctd data-start=\"4002\" data-end=\"4012\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"4012\" data-end=\"4018\" data-col-size=\"sm\"\u003eLCD\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4018\" data-end=\"4024\"\u003eLCD\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4024\" data-end=\"4031\"\u003eLCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4032\" data-end=\"4101\"\u003e\n\u003ctd data-start=\"4032\" data-end=\"4049\" data-col-size=\"sm\"\u003eControl System\u003c\/td\u003e\n\u003ctd data-start=\"4049\" data-end=\"4066\" data-col-size=\"sm\"\u003eMicroprocessor\u003c\/td\u003e\n\u003ctd data-start=\"4066\" data-end=\"4083\" data-col-size=\"sm\"\u003eMicroprocessor\u003c\/td\u003e\n\u003ctd data-start=\"4083\" data-end=\"4101\" data-col-size=\"sm\"\u003eMicroprocessor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4102\" data-end=\"4160\"\u003e\n\u003ctd data-start=\"4102\" data-end=\"4117\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"4117\" data-end=\"4131\" data-col-size=\"sm\"\u003e220–240V AC\u003c\/td\u003e\n\u003ctd data-start=\"4131\" data-end=\"4145\" data-col-size=\"sm\"\u003e220–240V AC\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4145\" data-end=\"4160\"\u003e220–240V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"4162\" data-end=\"4165\"\u003e\n\u003ch1 data-section-id=\"ohxjof\" data-start=\"4167\" data-end=\"4198\"\u003eStandards \u0026amp; Certification\u003c\/h1\u003e\n\u003cul data-start=\"4200\" data-end=\"4313\"\u003e\n\u003cli data-section-id=\"k988nn\" data-start=\"4200\" data-end=\"4230\"\u003eBIOBASE Manufactured Product\u003c\/li\u003e\n\u003cli data-section-id=\"17hgltt\" data-start=\"4231\" data-end=\"4263\"\u003eEuropean Class B Sterilisation\u003c\/li\u003e\n\u003cli data-section-id=\"13u47xl\" data-start=\"4264\" data-end=\"4278\"\u003eCE Certified\u003c\/li\u003e\n\u003cli data-section-id=\"vzlut2\" data-start=\"4279\" data-end=\"4313\"\u003eISO 13485 Certified Manufacturer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4315\" data-end=\"4318\"\u003e\n\u003ch1 data-section-id=\"niky1a\" data-start=\"4320\" data-end=\"4341\"\u003eWhat's Included\u003c\/h1\u003e\n\u003cul data-start=\"4343\" data-end=\"4520\"\u003e\n\u003cli data-section-id=\"jvopa5\" data-start=\"4343\" data-end=\"4398\"\u003eBIOBASE Class B Vertical Pulse Vacuum Steam Autoclave\u003c\/li\u003e\n\u003cli data-section-id=\"ffcjdo\" data-start=\"4399\" data-end=\"4438\"\u003eStainless steel sterilising basket(s)\u003c\/li\u003e\n\u003cli data-section-id=\"1forz9l\" data-start=\"4439\" data-end=\"4465\"\u003eBuilt-in thermal printer\u003c\/li\u003e\n\u003cli data-section-id=\"e5uu4u\" data-start=\"4466\" data-end=\"4492\"\u003eMobile temperature probe\u003c\/li\u003e\n\u003cli data-section-id=\"mv2eu6\" data-start=\"4493\" data-end=\"4506\"\u003ePower cable\u003c\/li\u003e\n\u003cli data-section-id=\"hg43yb\" data-start=\"4507\" data-end=\"4520\"\u003eUser manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4522\" data-end=\"4525\"\u003e\n\u003ch1 data-section-id=\"4fmhzf\" data-start=\"4527\" data-end=\"4552\"\u003eWarranty \u0026amp; Shipping\u003c\/h1\u003e\n\u003ch3 data-section-id=\"16fiq7\" data-start=\"4554\" data-end=\"4590\"\u003e12-Month Manufacturer's Warranty\u003c\/h3\u003e\n\u003cp data-start=\"4592\" data-end=\"4701\"\u003eAustralian customer support is provided for all BIOBASE autoclaves supplied by Australian Mycology Equipment.\u003c\/p\u003e\n\u003ch3 data-section-id=\"130532u\" data-start=\"4703\" data-end=\"4735\"\u003eFREE Australia-Wide Shipping\u003c\/h3\u003e\n\u003cp data-start=\"4737\" data-end=\"4796\"\u003eFREE Australia-wide shipping is included with this product.\u003c\/p\u003e\n\u003cp data-start=\"4798\" data-end=\"4979\"\u003eFor deliveries to remote, regional or difficult-to-access locations, additional freight charges may apply. If required, we will contact you with a freight quotation before dispatch.\u003c\/p\u003e","brand":"Australian Mycology Equipment","offers":[{"title":"BKQ-B50L","offer_id":51930630226208,"sku":null,"price":7450.0,"currency_code":"AUD","in_stock":true},{"title":"BKQ-B575L","offer_id":51930630258976,"sku":null,"price":8450.0,"currency_code":"AUD","in_stock":true},{"title":"BKQ-B5100L","offer_id":51930630291744,"sku":null,"price":10450.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0806\/0721\/5904\/files\/BKQ-B100L.jpg?v=1782916370","url":"https:\/\/australianmycologyequipment.com.au\/products\/biobase-vertical-pressure-steam-autoclave-35l-50l-75l-100l","provider":"Australian Mycology Equipment","version":"1.0","type":"link"}