{"title":"Featured products","description":null,"products":[{"product_id":"24-litre-steam-steriliser","title":"24L Portable Vertical Class N Steam Steriliser","description":"\u003ch1\u003e24L Portable Pressure Steam Steriliser\u003c\/h1\u003e\n\u003cp\u003eThe 24L Portable Pressure Steam Steriliser is a reliable benchtop sterilisation solution designed for laboratories, universities, schools, mycology, veterinary clinics and research facilities. Manufactured from high-quality stainless steel, it provides safe and effective sterilisation of laboratory instruments, glassware, culture media and other heat-resistant materials.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e24L Stainless Steel Chamber\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDigital Control Panel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdjustable Temperature \u0026amp; 0-99 Minute Timer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatic Heating Cycle\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePressure Gauge\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety Pressure Protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact Benchtop Design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e240V Operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eIdeal For\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eLaboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUniversities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSchools\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMycology\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVeterinary Clinics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResearch Facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial \u0026amp; Quality Control Laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWarranty\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e12-Month Manufacturer's Warranty\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAustralian Customer Support\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOnline Technical Support\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e This steriliser must only be used with \u003cstrong\u003edistilled or demineralised water\u003c\/strong\u003e. Damage caused by the use of tap or untreated water is not covered under the manufacturer's warranty..\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFREE Australia-wide shipping\u003c\/strong\u003e is included with this product. For deliveries to remote, regional or difficult-to-access locations, additional freight charges may apply. If this is the case, we will contact you with a freight quotation for approval before processing your order.\u003c\/p\u003e","brand":"Australian Mycology Equipment","offers":[{"title":"Default Title","offer_id":51914176102688,"sku":null,"price":1150.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0806\/0721\/5904\/files\/24Litreautoclave.avif?v=1782399571"},{"product_id":"24l-class-b-pulse-vacuum-autoclave-printer-usb","title":"24L Class B Pulse Vacuum Steam Autoclave with Printer \u0026 USB","description":"\u003cp data-start=\"488\" data-end=\"756\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe 24L Class B Pulse Vacuum Steam Autoclave is a premium benchtop steriliser designed for laboratories, research facilities, universities, veterinary clinics, dental practices and medical environments requiring advanced sterilisation and complete cycle documentation.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"758\" data-end=\"1206\"\u003eUtilising a three-stage pulse vacuum system and automatic vacuum drying, this autoclave provides reliable sterilisation of wrapped and unwrapped instruments, hollow instruments, porous loads, laboratory glassware and other compatible heat-resistant items. A built-in thermal printer and USB data storage allow sterilisation records to be printed and digitally archived for quality assurance and record keeping. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"1208\" data-end=\"1211\"\u003e\n\u003ch1 data-section-id=\"1h67pi1\" data-start=\"1213\" data-end=\"1226\"\u003eFeatures\u003c\/h1\u003e\n\u003cul data-start=\"1228\" data-end=\"1862\"\u003e\n\u003cli data-section-id=\"n8rus3\" data-start=\"1228\" data-end=\"1257\"\u003e24L stainless steel chamber\u003c\/li\u003e\n\u003cli data-section-id=\"kk0wnb\" data-start=\"1258\" data-end=\"1303\"\u003eEuropean Class B pulse vacuum sterilisation\u003c\/li\u003e\n\u003cli data-section-id=\"1qitxqk\" data-start=\"1304\" data-end=\"1337\"\u003eThree-stage pulse vacuum system\u003c\/li\u003e\n\u003cli data-section-id=\"19he5k3\" data-start=\"1338\" data-end=\"1363\"\u003eAutomatic vacuum drying\u003c\/li\u003e\n\u003cli data-section-id=\"1forz9l\" data-start=\"1364\" data-end=\"1390\"\u003eBuilt-in thermal printer\u003c\/li\u003e\n\u003cli data-section-id=\"qqvrtj\" data-start=\"1391\" data-end=\"1423\"\u003eUSB sterilisation data storage\u003c\/li\u003e\n\u003cli data-section-id=\"1vuf1k3\" data-start=\"1424\" data-end=\"1445\"\u003eLCD digital display\u003c\/li\u003e\n\u003cli data-section-id=\"nke5i3\" data-start=\"1446\" data-end=\"1483\"\u003eMicroprocessor controlled operation\u003c\/li\u003e\n\u003cli data-section-id=\"dkuv4w\" data-start=\"1484\" data-end=\"1518\"\u003eAutomatic sterilisation programs\u003c\/li\u003e\n\u003cli data-section-id=\"1l25ehd\" data-start=\"1519\" data-end=\"1571\"\u003eAdjustable sterilisation temperature (105°C–134°C)\u003c\/li\u003e\n\u003cli data-section-id=\"nzf0q2\" data-start=\"1572\" data-end=\"1604\"\u003eAdjustable sterilisation timer\u003c\/li\u003e\n\u003cli data-section-id=\"1wkltpj\" data-start=\"1605\" data-end=\"1633\"\u003eBuilt-in Bowie \u0026amp; Dick test\u003c\/li\u003e\n\u003cli data-section-id=\"1i8gqas\" data-start=\"1634\" data-end=\"1652\"\u003eVacuum leak test\u003c\/li\u003e\n\u003cli data-section-id=\"n8uhy4\" data-start=\"1653\" data-end=\"1680\"\u003eAutomatic fault diagnosis\u003c\/li\u003e\n\u003cli data-section-id=\"6dag98\" data-start=\"1681\" data-end=\"1709\"\u003eSafety door locking system\u003c\/li\u003e\n\u003cli data-section-id=\"ga39q4\" data-start=\"1710\" data-end=\"1738\"\u003eLow water level protection\u003c\/li\u003e\n\u003cli data-section-id=\"1wqnqec\" data-start=\"1739\" data-end=\"1768\"\u003eOver-temperature protection\u003c\/li\u003e\n\u003cli data-section-id=\"q87x0t\" data-start=\"1769\" data-end=\"1795\"\u003eOver-pressure protection\u003c\/li\u003e\n\u003cli data-section-id=\"1jqzb15\" data-start=\"1796\" data-end=\"1862\"\u003e240V Australian compatible \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1864\" data-end=\"1867\"\u003e\n\u003ch1 data-section-id=\"1lf6p35\" data-start=\"1869\" data-end=\"1883\"\u003eIdeal For\u003c\/h1\u003e\n\u003cul data-start=\"1885\" data-end=\"2066\"\u003e\n\u003cli data-section-id=\"knhpoo\" data-start=\"1885\" data-end=\"1908\"\u003eMycology laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"tuv45w\" data-start=\"1909\" data-end=\"1932\"\u003eResearch laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"10gwr6y\" data-start=\"1933\" data-end=\"1947\"\u003eUniversities\u003c\/li\u003e\n\u003cli data-section-id=\"1nw46xw\" data-start=\"1948\" data-end=\"1968\"\u003eVeterinary clinics\u003c\/li\u003e\n\u003cli data-section-id=\"1cqhoj6\" data-start=\"1969\" data-end=\"1986\"\u003eMedical clinics\u003c\/li\u003e\n\u003cli data-section-id=\"1b32i3a\" data-start=\"1987\" data-end=\"2005\"\u003eDental practices\u003c\/li\u003e\n\u003cli data-section-id=\"60wbl6\" data-start=\"2006\" data-end=\"2035\"\u003ePharmaceutical laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"14jhzbb\" data-start=\"2036\" data-end=\"2066\"\u003eQuality control laboratories\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2068\" data-end=\"2071\"\u003e\n\u003ch1 data-section-id=\"1qk0eh9\" data-start=\"2073\" data-end=\"2096\"\u003eAvailable Variants\u003c\/h1\u003e\n\u003cul data-start=\"2098\" data-end=\"2108\"\u003e\n\u003cli data-section-id=\"6n0enc\" data-start=\"2098\" data-end=\"2108\"\u003e24 Litre\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2110\" data-end=\"2113\"\u003e\n\u003ch1 data-section-id=\"g1cszw\" data-start=\"2115\" data-end=\"2144\"\u003eTechnical Specifications\u003c\/h1\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2146\" data-end=\"2850\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2146\" data-end=\"2173\"\u003e\n\u003ctr data-start=\"2146\" data-end=\"2173\"\u003e\n\u003cth data-start=\"2146\" data-end=\"2162\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2162\" data-end=\"2173\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2201\" data-end=\"2850\"\u003e\n\u003ctr data-start=\"2201\" data-end=\"2233\"\u003e\n\u003ctd data-start=\"2201\" data-end=\"2220\" data-col-size=\"sm\"\u003eChamber Capacity\u003c\/td\u003e\n\u003ctd data-start=\"2220\" data-end=\"2233\" data-col-size=\"sm\"\u003e24 Litres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2234\" data-end=\"2267\"\u003e\n\u003ctd data-start=\"2234\" data-end=\"2256\" data-col-size=\"sm\"\u003eSterilisation Class\u003c\/td\u003e\n\u003ctd data-start=\"2256\" data-end=\"2267\" data-col-size=\"sm\"\u003eClass B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2268\" data-end=\"2306\"\u003e\n\u003ctd data-start=\"2268\" data-end=\"2287\" data-col-size=\"sm\"\u003eChamber Material\u003c\/td\u003e\n\u003ctd data-start=\"2287\" data-end=\"2306\" data-col-size=\"sm\"\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2307\" data-end=\"2350\"\u003e\n\u003ctd data-start=\"2307\" data-end=\"2335\" data-col-size=\"sm\"\u003eSterilisation Temperature\u003c\/td\u003e\n\u003ctd data-start=\"2335\" data-end=\"2350\" data-col-size=\"sm\"\u003e105°C–134°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2351\" data-end=\"2395\"\u003e\n\u003ctd data-start=\"2351\" data-end=\"2381\" data-col-size=\"sm\"\u003eMaximum Working Temperature\u003c\/td\u003e\n\u003ctd data-start=\"2381\" data-end=\"2395\" data-col-size=\"sm\"\u003e134°C ±1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2396\" data-end=\"2435\"\u003e\n\u003ctd data-start=\"2396\" data-end=\"2423\" data-col-size=\"sm\"\u003eMaximum Working Pressure\u003c\/td\u003e\n\u003ctd data-start=\"2423\" data-end=\"2435\" data-col-size=\"sm\"\u003e0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2436\" data-end=\"2464\"\u003e\n\u003ctd data-start=\"2436\" data-end=\"2451\" data-col-size=\"sm\"\u003eVacuum Level\u003c\/td\u003e\n\u003ctd data-start=\"2451\" data-end=\"2464\" data-col-size=\"sm\"\u003e-0.08 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2465\" data-end=\"2489\"\u003e\n\u003ctd data-start=\"2465\" data-end=\"2473\" data-col-size=\"sm\"\u003eTimer\u003c\/td\u003e\n\u003ctd data-start=\"2473\" data-end=\"2489\" data-col-size=\"sm\"\u003e0–99 Minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2490\" data-end=\"2520\"\u003e\n\u003ctd data-start=\"2490\" data-end=\"2504\" data-col-size=\"sm\"\u003eDrying Time\u003c\/td\u003e\n\u003ctd data-start=\"2504\" data-end=\"2520\" data-col-size=\"sm\"\u003e0–99 Minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2521\" data-end=\"2572\"\u003e\n\u003ctd data-start=\"2521\" data-end=\"2542\" data-col-size=\"sm\"\u003eChamber Dimensions\u003c\/td\u003e\n\u003ctd data-start=\"2542\" data-end=\"2572\" data-col-size=\"sm\"\u003eManufacturer specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2573\" data-end=\"2617\"\u003e\n\u003ctd data-start=\"2573\" data-end=\"2595\" data-col-size=\"sm\"\u003eExternal Dimensions\u003c\/td\u003e\n\u003ctd data-start=\"2595\" data-end=\"2617\" data-col-size=\"sm\"\u003e580 × 480 × 380 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2618\" data-end=\"2663\"\u003e\n\u003ctd data-start=\"2618\" data-end=\"2641\" data-col-size=\"sm\"\u003eTransport Dimensions\u003c\/td\u003e\n\u003ctd data-start=\"2641\" data-end=\"2663\" data-col-size=\"sm\"\u003e800 × 580 × 500 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2664\" data-end=\"2686\"\u003e\n\u003ctd data-start=\"2664\" data-end=\"2677\" data-col-size=\"sm\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd data-start=\"2677\" data-end=\"2686\" data-col-size=\"sm\"\u003e62 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2687\" data-end=\"2711\"\u003e\n\u003ctd data-start=\"2687\" data-end=\"2702\" data-col-size=\"sm\"\u003eGross Weight\u003c\/td\u003e\n\u003ctd data-start=\"2702\" data-end=\"2711\" data-col-size=\"sm\"\u003e68 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2712\" data-end=\"2744\"\u003e\n\u003ctd data-start=\"2712\" data-end=\"2727\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"2727\" data-end=\"2744\" data-col-size=\"sm\"\u003eAC 220V, 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2745\" data-end=\"2767\"\u003e\n\u003ctd data-start=\"2745\" data-end=\"2755\" data-col-size=\"sm\"\u003ePrinter\u003c\/td\u003e\n\u003ctd data-start=\"2755\" data-end=\"2767\" data-col-size=\"sm\"\u003eBuilt-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2768\" data-end=\"2850\"\u003e\n\u003ctd data-start=\"2768\" data-end=\"2774\" data-col-size=\"sm\"\u003eUSB\u003c\/td\u003e\n\u003ctd data-start=\"2774\" data-end=\"2811\" data-col-size=\"sm\"\u003eBuilt-in sterilisation data export\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"2852\" data-end=\"2855\"\u003e\n\u003ch1 data-section-id=\"ohxjof\" data-start=\"2857\" data-end=\"2888\"\u003eStandards \u0026amp; Certification\u003c\/h1\u003e\n\u003cul data-start=\"2890\" data-end=\"3047\"\u003e\n\u003cli data-section-id=\"13u47xl\" data-start=\"2890\" data-end=\"2904\"\u003eCE Certified\u003c\/li\u003e\n\u003cli data-section-id=\"vzlut2\" data-start=\"2905\" data-end=\"2939\"\u003eISO 13485 Certified Manufacturer\u003c\/li\u003e\n\u003cli data-section-id=\"5fi78e\" data-start=\"2940\" data-end=\"2967\"\u003eFDA Listed (manufacturer)\u003c\/li\u003e\n\u003cli data-section-id=\"1jghg13\" data-start=\"2968\" data-end=\"3047\"\u003eEuropean Class B sterilisation standard \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3049\" data-end=\"3052\"\u003e\n\u003ch1 data-section-id=\"niky1a\" data-start=\"3054\" data-end=\"3075\"\u003eWhat's Included\u003c\/h1\u003e\n\u003cul data-start=\"3077\" data-end=\"3231\"\u003e\n\u003cli data-section-id=\"1udh5dm\" data-start=\"3077\" data-end=\"3113\"\u003e24L Class B Pulse Vacuum Autoclave\u003c\/li\u003e\n\u003cli data-section-id=\"tahgpy\" data-start=\"3114\" data-end=\"3137\"\u003eStainless steel trays\u003c\/li\u003e\n\u003cli data-section-id=\"18rw2wd\" data-start=\"3138\" data-end=\"3149\"\u003eTray rack\u003c\/li\u003e\n\u003cli data-section-id=\"1forz9l\" data-start=\"3150\" data-end=\"3176\"\u003eBuilt-in thermal printer\u003c\/li\u003e\n\u003cli data-section-id=\"862fvr\" data-start=\"3177\" data-end=\"3204\"\u003eUSB data storage function\u003c\/li\u003e\n\u003cli data-section-id=\"dlvklp\" data-start=\"3205\" data-end=\"3217\"\u003ePower cord\u003c\/li\u003e\n\u003cli data-section-id=\"hg43yb\" data-start=\"3218\" data-end=\"3231\"\u003eUser manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3233\" data-end=\"3236\"\u003e\n\u003ch1 data-section-id=\"4fmhzf\" data-start=\"3238\" data-end=\"3263\"\u003eWarranty \u0026amp; Shipping\u003c\/h1\u003e\n\u003ch3 data-section-id=\"16fiq7\" data-start=\"3265\" data-end=\"3301\"\u003e12-Month Manufacturer's Warranty\u003c\/h3\u003e\n\u003cp data-start=\"3303\" data-end=\"3404\"\u003eAustralian customer support is provided for all autoclaves supplied by Australian Mycology Equipment.\u003c\/p\u003e\n\u003ch3 data-section-id=\"130532u\" data-start=\"3406\" data-end=\"3438\"\u003eFREE Australia-Wide Shipping\u003c\/h3\u003e\n\u003cp data-start=\"3440\" data-end=\"3499\"\u003eFREE Australia-wide shipping is included with this product.\u003c\/p\u003e\n\u003cp data-start=\"3501\" data-end=\"3682\"\u003eFor deliveries to remote, regional or difficult-to-access locations, additional freight charges may apply. If required, we will contact you with a freight quotation before dispatch.\u003c\/p\u003e\n\u003chr data-start=\"3684\" data-end=\"3687\"\u003e\n\u003ch1 data-section-id=\"p538tw\" data-start=\"3689\" data-end=\"3706\"\u003ePlease Note\u003c\/h1\u003e\n\u003cp data-start=\"3708\" data-end=\"3910\"\u003eThis Class B pulse vacuum autoclave is suitable for sterilising wrapped and unwrapped solid instruments, hollow instruments, porous loads, laboratory glassware and other compatible heat-resistant items.\u003c\/p\u003e\n\u003cp data-start=\"3912\" data-end=\"4043\"\u003eSterilisation records can be printed using the built-in thermal printer and exported via USB for digital storage and documentation.\u003c\/p\u003e\n\u003cp data-start=\"4045\" data-end=\"4193\"\u003eUse only distilled or demineralised water. Damage caused by tap water, bore water, rainwater or other untreated water is not covered under warranty.\u003c\/p\u003e","brand":"Australian Mycology Equipment","offers":[{"title":"Default Title","offer_id":51927512908064,"sku":null,"price":3950.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0806\/0721\/5904\/files\/TM-XD24DV.png?v=1784129882"},{"product_id":"class-b-vertical-pulse-vacuum-steam-autoclave-50l-75l-100l","title":"Class B Vertical Pulse Vacuum Steam Autoclave (35L, 50L, 75L \u0026 100L)","description":"\u003cp data-start=\"668\" data-end=\"975\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"672\" data-end=\"742\"\u003eClass B Vertical Pulse Vacuum Steam Autoclave with Drying Function\u003c\/strong\u003e is a premium laboratory steriliser designed for research laboratories, universities, veterinary clinics, pharmaceutical facilities and industrial laboratories requiring advanced steam sterilisation and dependable drying performance.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"977\" data-end=\"1230\"\u003eAvailable in \u003cstrong data-start=\"990\" data-end=\"1016\"\u003e35L, 50L, 75L and 100L\u003c\/strong\u003e capacities, this fully automatic autoclave combines pulse vacuum technology with an integrated drying function to deliver excellent steam penetration, efficient air removal and improved drying of sterilised loads.\u003c\/p\u003e\n\u003cp data-start=\"1232\" data-end=\"1648\"\u003eA closed \u003cstrong data-start=\"1241\" data-end=\"1281\"\u003esteam-water inner circulation system\u003c\/strong\u003e minimises steam discharge into the laboratory, helping maintain a cleaner and drier working environment while improving operating efficiency. Microprocessor-controlled operation automatically manages pressure, temperature and sterilisation time throughout each cycle, providing reliable and repeatable sterilisation performance for demanding laboratory applications.\u003c\/p\u003e\n\u003cp data-start=\"1650\" data-end=\"1826\"\u003eSuitable for sterilising wrapped and unwrapped instruments, porous materials, hollow instruments, laboratory glassware, culture media and other compatible heat-resistant items.\u003c\/p\u003e\n\u003chr data-start=\"1828\" data-end=\"1831\"\u003e\n\u003ch1 data-section-id=\"1h67pi1\" data-start=\"1833\" data-end=\"1846\"\u003eFeatures\u003c\/h1\u003e\n\u003cul data-start=\"1848\" data-end=\"2760\"\u003e\n\u003cli data-section-id=\"cz6i8v\" data-start=\"1848\" data-end=\"1896\"\u003eAvailable in 35L, 50L, 75L and 100L capacities\u003c\/li\u003e\n\u003cli data-section-id=\"kk0wnb\" data-start=\"1897\" data-end=\"1942\"\u003eEuropean Class B pulse vacuum sterilisation\u003c\/li\u003e\n\u003cli data-section-id=\"1bv6mcv\" data-start=\"1943\" data-end=\"1981\"\u003eIntegrated automatic drying function\u003c\/li\u003e\n\u003cli data-section-id=\"1t1km2n\" data-start=\"1982\" data-end=\"2015\"\u003ePulse vacuum air removal system\u003c\/li\u003e\n\u003cli data-section-id=\"662few\" data-start=\"2016\" data-end=\"2061\"\u003eClosed steam-water inner circulation system\u003c\/li\u003e\n\u003cli data-section-id=\"1sc37ie\" data-start=\"2062\" data-end=\"2109\"\u003eMinimises steam discharge into the laboratory\u003c\/li\u003e\n\u003cli data-section-id=\"14q1rao\" data-start=\"2110\" data-end=\"2163\"\u003eHelps maintain a cleaner, drier working environment\u003c\/li\u003e\n\u003cli data-section-id=\"c9m3xq\" data-start=\"2164\" data-end=\"2202\"\u003eFully automatic sterilisation cycles\u003c\/li\u003e\n\u003cli data-section-id=\"8oc9au\" data-start=\"2203\" data-end=\"2240\"\u003eMicroprocessor-controlled operation\u003c\/li\u003e\n\u003cli data-section-id=\"109oo1y\" data-start=\"2241\" data-end=\"2270\"\u003eDigital touch control panel\u003c\/li\u003e\n\u003cli data-section-id=\"8ws0uo\" data-start=\"2271\" data-end=\"2315\"\u003eAutomatic pressure and temperature control\u003c\/li\u003e\n\u003cli data-section-id=\"16gwqf5\" data-start=\"2316\" data-end=\"2354\"\u003eAdjustable sterilisation temperature\u003c\/li\u003e\n\u003cli data-section-id=\"nzf0q2\" data-start=\"2355\" data-end=\"2387\"\u003eAdjustable sterilisation timer\u003c\/li\u003e\n\u003cli data-section-id=\"xezimq\" data-start=\"2388\" data-end=\"2418\"\u003eQuick-opening handwheel door\u003c\/li\u003e\n\u003cli data-section-id=\"6dag98\" data-start=\"2419\" data-end=\"2447\"\u003eSafety door locking system\u003c\/li\u003e\n\u003cli data-section-id=\"eqf2d0\" data-start=\"2448\" data-end=\"2483\"\u003eSelf-inflating silicone door seal\u003c\/li\u003e\n\u003cli data-section-id=\"obo47c\" data-start=\"2484\" data-end=\"2514\"\u003eSafety pressure relief valve\u003c\/li\u003e\n\u003cli data-section-id=\"g36og4\" data-start=\"2515\" data-end=\"2561\"\u003eAutomatic power shut-off after sterilisation\u003c\/li\u003e\n\u003cli data-section-id=\"1otc7j1\" data-start=\"2562\" data-end=\"2594\"\u003eAudible cycle completion alarm\u003c\/li\u003e\n\u003cli data-section-id=\"ga39q4\" data-start=\"2595\" data-end=\"2623\"\u003eLow water level protection\u003c\/li\u003e\n\u003cli data-section-id=\"1wqnqec\" data-start=\"2624\" data-end=\"2653\"\u003eOver-temperature protection\u003c\/li\u003e\n\u003cli data-section-id=\"q87x0t\" data-start=\"2654\" data-end=\"2680\"\u003eOver-pressure protection\u003c\/li\u003e\n\u003cli data-section-id=\"u2sidl\" data-start=\"2681\" data-end=\"2731\"\u003eTwo stainless steel sterilising baskets included\u003c\/li\u003e\n\u003cli data-section-id=\"ur2hz8\" data-start=\"2732\" data-end=\"2760\"\u003e240V Australian compatible\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2762\" data-end=\"2765\"\u003e\n\u003ch1 data-section-id=\"1lf6p35\" data-start=\"2767\" data-end=\"2781\"\u003eIdeal For\u003c\/h1\u003e\n\u003cul data-start=\"2783\" data-end=\"3031\"\u003e\n\u003cli data-section-id=\"knhpoo\" data-start=\"2783\" data-end=\"2806\"\u003eMycology laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"tuv45w\" data-start=\"2807\" data-end=\"2830\"\u003eResearch laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"10gwr6y\" data-start=\"2831\" data-end=\"2845\"\u003eUniversities\u003c\/li\u003e\n\u003cli data-section-id=\"1nw46xw\" data-start=\"2846\" data-end=\"2866\"\u003eVeterinary clinics\u003c\/li\u003e\n\u003cli data-section-id=\"1el0e8\" data-start=\"2867\" data-end=\"2887\"\u003eMedical facilities\u003c\/li\u003e\n\u003cli data-section-id=\"60wbl6\" data-start=\"2888\" data-end=\"2917\"\u003ePharmaceutical laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1or0uhb\" data-start=\"2918\" data-end=\"2946\"\u003eBiotechnology laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"14jhzbb\" data-start=\"2947\" data-end=\"2977\"\u003eQuality control laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1pcjfkp\" data-start=\"2978\" data-end=\"3005\"\u003eFood testing laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"10vtoei\" data-start=\"3006\" data-end=\"3031\"\u003eIndustrial laboratories\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3033\" data-end=\"3036\"\u003e\n\u003ch1 data-section-id=\"1qk0eh9\" data-start=\"3038\" data-end=\"3061\"\u003eAvailable Variants\u003c\/h1\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3063\" data-end=\"3203\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3063\" data-end=\"3083\"\u003e\n\u003ctr data-start=\"3063\" data-end=\"3083\"\u003e\n\u003cth data-start=\"3063\" data-end=\"3071\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eModel\u003c\/th\u003e\n\u003cth data-start=\"3071\" data-end=\"3083\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eCapacity\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3106\" data-end=\"3203\"\u003e\n\u003ctr data-start=\"3106\" data-end=\"3129\"\u003e\n\u003ctd data-start=\"3106\" data-end=\"3116\" data-col-size=\"sm\"\u003eLS-35HV\u003c\/td\u003e\n\u003ctd data-start=\"3116\" data-end=\"3129\" data-col-size=\"sm\"\u003e35 Litres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3130\" data-end=\"3153\"\u003e\n\u003ctd data-start=\"3130\" data-end=\"3140\" data-col-size=\"sm\"\u003eLS-50HV\u003c\/td\u003e\n\u003ctd data-start=\"3140\" data-end=\"3153\" data-col-size=\"sm\"\u003e50 Litres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3154\" data-end=\"3177\"\u003e\n\u003ctd data-start=\"3154\" data-end=\"3164\" data-col-size=\"sm\"\u003eLS-75HV\u003c\/td\u003e\n\u003ctd data-start=\"3164\" data-end=\"3177\" data-col-size=\"sm\"\u003e75 Litres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3178\" data-end=\"3203\"\u003e\n\u003ctd data-start=\"3178\" data-end=\"3189\" data-col-size=\"sm\"\u003eLS-100HV\u003c\/td\u003e\n\u003ctd data-start=\"3189\" data-end=\"3203\" data-col-size=\"sm\"\u003e100 Litres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"3205\" data-end=\"3208\"\u003e\n\u003ch1 data-section-id=\"g1cszw\" data-start=\"3210\" data-end=\"3239\"\u003eTechnical Specifications\u003c\/h1\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3241\" data-end=\"4021\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3241\" data-end=\"3268\"\u003e\n\u003ctr data-start=\"3241\" data-end=\"3268\"\u003e\n\u003cth data-start=\"3241\" data-end=\"3257\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"3257\" data-end=\"3268\" data-col-size=\"md\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3296\" data-end=\"4021\"\u003e\n\u003ctr data-start=\"3296\" data-end=\"3329\"\u003e\n\u003ctd data-start=\"3296\" data-end=\"3318\" data-col-size=\"sm\"\u003eSterilisation Class\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3318\" data-end=\"3329\"\u003eClass B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3330\" data-end=\"3377\"\u003e\n\u003ctd data-start=\"3330\" data-end=\"3353\" data-col-size=\"sm\"\u003eAvailable Capacities\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3353\" data-end=\"3377\"\u003e35L, 50L, 75L \u0026amp; 100L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3378\" data-end=\"3423\"\u003e\n\u003ctd data-start=\"3378\" data-end=\"3401\" data-col-size=\"sm\"\u003eSterilisation Method\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3401\" data-end=\"3423\"\u003ePulse Vacuum Steam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3424\" data-end=\"3455\"\u003e\n\u003ctd data-start=\"3424\" data-end=\"3442\" data-col-size=\"sm\"\u003eDrying Function\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3442\" data-end=\"3455\"\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3456\" data-end=\"3494\"\u003e\n\u003ctd data-start=\"3456\" data-end=\"3475\" data-col-size=\"sm\"\u003eChamber Material\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3475\" data-end=\"3494\"\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3495\" data-end=\"3535\"\u003e\n\u003ctd data-start=\"3495\" data-end=\"3510\" data-col-size=\"sm\"\u003eConstruction\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3510\" data-end=\"3535\"\u003eFully Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3536\" data-end=\"3565\"\u003e\n\u003ctd data-start=\"3536\" data-end=\"3553\" data-col-size=\"sm\"\u003eChamber Design\u003c\/td\u003e\n\u003ctd data-start=\"3553\" data-end=\"3565\" data-col-size=\"md\"\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3566\" data-end=\"3612\"\u003e\n\u003ctd data-start=\"3566\" data-end=\"3583\" data-col-size=\"sm\"\u003eControl System\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3583\" data-end=\"3612\"\u003eMicroprocessor Controlled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3613\" data-end=\"3648\"\u003e\n\u003ctd data-start=\"3613\" data-end=\"3623\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3623\" data-end=\"3648\"\u003eDigital Touch Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3649\" data-end=\"3704\"\u003e\n\u003ctd data-start=\"3649\" data-end=\"3664\" data-col-size=\"sm\"\u003eSteam System\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3664\" data-end=\"3704\"\u003eClosed Steam-Water Inner Circulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3705\" data-end=\"3736\"\u003e\n\u003ctd data-start=\"3705\" data-end=\"3724\" data-col-size=\"sm\"\u003eWorking Pressure\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3724\" data-end=\"3736\"\u003e0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3737\" data-end=\"3768\"\u003e\n\u003ctd data-start=\"3737\" data-end=\"3759\" data-col-size=\"sm\"\u003eMaximum Temperature\u003c\/td\u003e\n\u003ctd data-start=\"3759\" data-end=\"3768\" data-col-size=\"md\"\u003e134°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3769\" data-end=\"3801\"\u003e\n\u003ctd data-start=\"3769\" data-end=\"3788\" data-col-size=\"sm\"\u003ePressure Control\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3788\" data-end=\"3801\"\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3802\" data-end=\"3837\"\u003e\n\u003ctd data-start=\"3802\" data-end=\"3824\" data-col-size=\"sm\"\u003eTemperature Control\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3824\" data-end=\"3837\"\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3838\" data-end=\"3938\"\u003e\n\u003ctd data-start=\"3838\" data-end=\"3855\" data-col-size=\"sm\"\u003eSafety Systems\u003c\/td\u003e\n\u003ctd data-start=\"3855\" data-end=\"3938\" data-col-size=\"md\"\u003eDoor lock, pressure relief valve, over-temperature and over-pressure protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3939\" data-end=\"3984\"\u003e\n\u003ctd data-start=\"3939\" data-end=\"3961\" data-col-size=\"sm\"\u003eSterilising Baskets\u003c\/td\u003e\n\u003ctd data-start=\"3961\" data-end=\"3984\" data-col-size=\"md\"\u003eTwo Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3985\" data-end=\"4021\"\u003e\n\u003ctd data-start=\"3985\" data-end=\"4000\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"4000\" data-end=\"4021\" data-col-size=\"md\"\u003e220–240V AC, 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"4023\" data-end=\"4026\"\u003e\n\u003ch1 data-section-id=\"ohxjof\" data-start=\"4028\" data-end=\"4059\"\u003eStandards \u0026amp; Certification\u003c\/h1\u003e\n\u003cul data-start=\"4061\" data-end=\"4207\"\u003e\n\u003cli data-section-id=\"13u47xl\" data-start=\"4061\" data-end=\"4075\"\u003eCE Certified\u003c\/li\u003e\n\u003cli data-section-id=\"1iqzxlp\" data-start=\"4076\" data-end=\"4113\"\u003eISO 13485 Quality Management System\u003c\/li\u003e\n\u003cli data-section-id=\"mya17r\" data-start=\"4114\" data-end=\"4157\"\u003eEuropean Class B sterilisation technology\u003c\/li\u003e\n\u003cli data-section-id=\"cr2o7d\" data-start=\"4158\" data-end=\"4207\"\u003eManufacturer compliance documentation available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4209\" data-end=\"4212\"\u003e\n\u003ch1 data-section-id=\"niky1a\" data-start=\"4214\" data-end=\"4235\"\u003eWhat's Included\u003c\/h1\u003e\n\u003cul data-start=\"4237\" data-end=\"4354\"\u003e\n\u003cli data-section-id=\"e3xhsc\" data-start=\"4237\" data-end=\"4284\"\u003eClass B Vertical Pulse Vacuum Steam Autoclave\u003c\/li\u003e\n\u003cli data-section-id=\"s469qp\" data-start=\"4285\" data-end=\"4326\"\u003eTwo stainless steel sterilising baskets\u003c\/li\u003e\n\u003cli data-section-id=\"mv2eu6\" data-start=\"4327\" data-end=\"4340\"\u003ePower cable\u003c\/li\u003e\n\u003cli data-section-id=\"hg43yb\" data-start=\"4341\" data-end=\"4354\"\u003eUser manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4356\" data-end=\"4359\"\u003e\n\u003ch1 data-section-id=\"4fmhzf\" data-start=\"4361\" data-end=\"4386\"\u003eWarranty \u0026amp; Shipping\u003c\/h1\u003e\n\u003ch3 data-section-id=\"16fiq7\" data-start=\"4388\" data-end=\"4424\"\u003e12-Month Manufacturer's Warranty\u003c\/h3\u003e\n\u003cp data-start=\"4426\" data-end=\"4527\"\u003eAustralian customer support is provided for all autoclaves supplied by Australian Mycology Equipment.\u003c\/p\u003e\n\u003ch3 data-section-id=\"130532u\" data-start=\"4529\" data-end=\"4561\"\u003eFREE Australia-Wide Shipping\u003c\/h3\u003e\n\u003cp data-start=\"4563\" data-end=\"4622\"\u003eFREE Australia-wide shipping is included with this product.\u003c\/p\u003e\n\u003cp data-start=\"4624\" data-end=\"4805\"\u003eFor deliveries to remote, regional or difficult-to-access locations, additional freight charges may apply. If required, we will contact you with a freight quotation before dispatch.\u003c\/p\u003e\n\u003chr data-start=\"4807\" data-end=\"4810\"\u003e\n\u003ch1 data-section-id=\"p538tw\" data-start=\"4812\" data-end=\"4829\"\u003ePlease Note\u003c\/h1\u003e\n\u003cp data-start=\"4831\" data-end=\"5046\"\u003eThis Class B pulse vacuum autoclave is designed for sterilising wrapped and unwrapped instruments, hollow instruments, porous materials, laboratory glassware, culture media and other compatible heat-resistant items.\u003c\/p\u003e\n\u003cp data-start=\"5048\" data-end=\"5333\"\u003eThe integrated pulse vacuum system improves steam penetration, while the automatic drying function helps reduce residual moisture after sterilisation. The closed steam-water circulation system also minimises steam discharge, helping maintain a cleaner and drier laboratory environment.\u003c\/p\u003e\n\u003cp data-start=\"5335\" data-end=\"5483\"\u003eUse only distilled or demineralised water. Damage caused by tap water, bore water, rainwater or other untreated water is not covered under warranty.\u003c\/p\u003e\n\u003chr data-start=\"5485\" data-end=\"5488\"\u003e","brand":"Australian Mycology Equipment","offers":[{"title":"LS-135HV 35 Litre","offer_id":51934149247264,"sku":null,"price":6250.0,"currency_code":"AUD","in_stock":true},{"title":"LS-50HV 50 Litres","offer_id":51934149280032,"sku":null,"price":6950.0,"currency_code":"AUD","in_stock":true},{"title":"LS-75HV 75 Litres","offer_id":51934149312800,"sku":null,"price":7950.0,"currency_code":"AUD","in_stock":true},{"title":"LS-100HV 100 Litres","offer_id":51934149345568,"sku":null,"price":9950.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0806\/0721\/5904\/files\/100L-Vertical-Autoclave-High-Pressure-Steam-Sterilizer.jpg_480x480_7ff48f38-2bc0-4425-a17f-29ffaafd04f9.avif?v=1782882292"},{"product_id":"biobase-vertical-pressure-steam-autoclave-50l-75l","title":"BIOBASE BKQ-ZI Class B Vertical Steam Autoclave (50L, 75L \u0026 100L)","description":"\u003cp data-start=\"548\" data-end=\"824\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"552\" data-end=\"596\"\u003eBIOBASE Class B Vertical Steam Autoclave\u003c\/strong\u003e is a professional laboratory steriliser designed for universities, research laboratories, pharmaceutical facilities, food testing laboratories and industrial environments requiring dependable, high-capacity steam sterilisation.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"826\" data-end=\"1164\"\u003eAvailable in \u003cstrong data-start=\"839\" data-end=\"860\"\u003e50L, 75L and 100L\u003c\/strong\u003e capacities, the BKQ-Z Series combines intelligent microprocessor control with fully automatic heating, sterilisation and exhaust cycles to provide reliable sterilisation of wrapped and unwrapped instruments, laboratory glassware, dressings, rubber items, culture media and compatible laboratory liquids.\u003c\/p\u003e\n\u003cp data-start=\"1166\" data-end=\"1615\"\u003eDesigned for busy laboratory environments, the BKQ-Z Series features a \u003cstrong data-start=\"1237\" data-end=\"1274\"\u003espring-assisted quick-opening lid\u003c\/strong\u003e that makes the heavy lid effortless to lift while reducing operator fatigue. The enclosed lid design also helps minimise accidental contact with hot metal surfaces after sterilisation, improving both operator comfort and safety. Heavy-duty castors make the unit easy to position, while the quick-access service panel simplifies maintenance.\u003c\/p\u003e\n\u003cp data-start=\"1617\" data-end=\"1981\"\u003eWith multiple sterilisation programs, a durable SUS304 stainless steel chamber, intelligent safety protection systems, real-time cycle monitoring and an optional built-in thermal printer for sterilisation record keeping, the BIOBASE BKQ-Z Series delivers dependable performance, ease of operation and long-term reliability for professional laboratory applications.\u003c\/p\u003e\n\u003chr data-start=\"1983\" data-end=\"1986\"\u003e\n\u003ch1 data-section-id=\"1h67pi1\" data-start=\"1988\" data-end=\"2001\"\u003eFeatures\u003c\/h1\u003e\n\u003cul data-start=\"2003\" data-end=\"3031\"\u003e\n\u003cli data-section-id=\"hbz4ft\" data-start=\"2003\" data-end=\"2050\"\u003eAvailable in \u003cstrong data-start=\"2018\" data-end=\"2039\"\u003e50L, 75L and 100L\u003c\/strong\u003e capacities\u003c\/li\u003e\n\u003cli data-section-id=\"kef9m5\" data-start=\"2051\" data-end=\"2073\"\u003eBIOBASE BKQ-Z Series\u003c\/li\u003e\n\u003cli data-section-id=\"15613x4\" data-start=\"2074\" data-end=\"2103\"\u003eClass B steam sterilisation\u003c\/li\u003e\n\u003cli data-section-id=\"1emjsyv\" data-start=\"2104\" data-end=\"2129\"\u003eFully automatic heating\u003c\/li\u003e\n\u003cli data-section-id=\"grlhzh\" data-start=\"2130\" data-end=\"2161\"\u003eFully automatic sterilisation\u003c\/li\u003e\n\u003cli data-section-id=\"kxva1\" data-start=\"2162\" data-end=\"2187\"\u003eFully automatic exhaust\u003c\/li\u003e\n\u003cli data-section-id=\"1r4edb8\" data-start=\"2188\" data-end=\"2224\"\u003eIntelligent microprocessor control\u003c\/li\u003e\n\u003cli data-section-id=\"14ee5wn\" data-start=\"2225\" data-end=\"2260\"\u003eSpring-assisted quick-opening lid\u003c\/li\u003e\n\u003cli data-section-id=\"10oc8wq\" data-start=\"2261\" data-end=\"2335\"\u003eFully enclosed lid design to reduce accidental contact with hot surfaces\u003c\/li\u003e\n\u003cli data-section-id=\"14e4jvt\" data-start=\"2336\" data-end=\"2382\"\u003eSUS304 stainless steel sterilisation chamber\u003c\/li\u003e\n\u003cli data-section-id=\"67ictm\" data-start=\"2383\" data-end=\"2456\"\u003eLED display showing temperature, time, alarm codes and operating status\u003c\/li\u003e\n\u003cli data-section-id=\"1rm18k8\" data-start=\"2457\" data-end=\"2499\"\u003eReal-time chamber temperature monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"m1mizr\" data-start=\"2500\" data-end=\"2527\"\u003eInternal steam generation\u003c\/li\u003e\n\u003cli data-section-id=\"1efhp4c\" data-start=\"2528\" data-end=\"2556\"\u003eWrapped instrument program\u003c\/li\u003e\n\u003cli data-section-id=\"13hcfbr\" data-start=\"2557\" data-end=\"2587\"\u003eUnwrapped instrument program\u003c\/li\u003e\n\u003cli data-section-id=\"t28jdb\" data-start=\"2588\" data-end=\"2606\"\u003eDressing program\u003c\/li\u003e\n\u003cli data-section-id=\"31fr70\" data-start=\"2607\" data-end=\"2623\"\u003eRubber program\u003c\/li\u003e\n\u003cli data-section-id=\"4qf4sw\" data-start=\"2624\" data-end=\"2640\"\u003eLiquid program\u003c\/li\u003e\n\u003cli data-section-id=\"1le8szn\" data-start=\"2641\" data-end=\"2664\"\u003eLiquid custom program\u003c\/li\u003e\n\u003cli data-section-id=\"1xj89oy\" data-start=\"2665\" data-end=\"2687\"\u003eSolid custom program\u003c\/li\u003e\n\u003cli data-section-id=\"v5qnp9\" data-start=\"2688\" data-end=\"2740\"\u003eSelf-expanding medical-grade silicone sealing ring\u003c\/li\u003e\n\u003cli data-section-id=\"ao4kvc\" data-start=\"2741\" data-end=\"2763\"\u003eManual water filling\u003c\/li\u003e\n\u003cli data-section-id=\"k26l9b\" data-start=\"2764\" data-end=\"2792\"\u003eEnd-of-cycle audible alarm\u003c\/li\u003e\n\u003cli data-section-id=\"eb140g\" data-start=\"2793\" data-end=\"2822\"\u003eHeavy-duty lockable castors\u003c\/li\u003e\n\u003cli data-section-id=\"8bnz0v\" data-start=\"2823\" data-end=\"2855\"\u003eQuick-access maintenance panel\u003c\/li\u003e\n\u003cli data-section-id=\"12q9c1z\" data-start=\"2856\" data-end=\"2891\"\u003eOptional built-in thermal printer\u003c\/li\u003e\n\u003cli data-section-id=\"xetbwr\" data-start=\"2892\" data-end=\"2925\"\u003eOptional stainless steel bucket\u003c\/li\u003e\n\u003cli data-section-id=\"1fcyn68\" data-start=\"2926\" data-end=\"2955\"\u003eOptional mesh bottom basket\u003c\/li\u003e\n\u003cli data-section-id=\"1fkuln0\" data-start=\"2956\" data-end=\"3002\"\u003eMultiple automatic safety protection systems\u003c\/li\u003e\n\u003cli data-section-id=\"ur2hz8\" data-start=\"3003\" data-end=\"3031\"\u003e240V Australian compatible\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3033\" data-end=\"3036\"\u003e\n\u003ch1 data-section-id=\"1lf6p35\" data-start=\"3038\" data-end=\"3052\"\u003eIdeal For\u003c\/h1\u003e\n\u003cul data-start=\"3054\" data-end=\"3454\"\u003e\n\u003cli data-section-id=\"knhpoo\" data-start=\"3054\" data-end=\"3077\"\u003eMycology laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"tuv45w\" data-start=\"3078\" data-end=\"3101\"\u003eResearch laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"10gwr6y\" data-start=\"3102\" data-end=\"3116\"\u003eUniversities\u003c\/li\u003e\n\u003cli data-section-id=\"60wbl6\" data-start=\"3117\" data-end=\"3146\"\u003ePharmaceutical laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1or0uhb\" data-start=\"3147\" data-end=\"3175\"\u003eBiotechnology laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1pcjfkp\" data-start=\"3176\" data-end=\"3203\"\u003eFood testing laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"l94mk0\" data-start=\"3204\" data-end=\"3229\"\u003eVeterinary laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"qg6mxy\" data-start=\"3230\" data-end=\"3252\"\u003eMedical laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"14jhzbb\" data-start=\"3253\" data-end=\"3283\"\u003eQuality control laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"10vtoei\" data-start=\"3284\" data-end=\"3309\"\u003eIndustrial laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1yjgfdw\" data-start=\"3310\" data-end=\"3343\"\u003eSterilising wrapped instruments\u003c\/li\u003e\n\u003cli data-section-id=\"15j0iyn\" data-start=\"3344\" data-end=\"3379\"\u003eSterilising unwrapped instruments\u003c\/li\u003e\n\u003cli data-section-id=\"4k27eo\" data-start=\"3380\" data-end=\"3402\"\u003eLaboratory glassware\u003c\/li\u003e\n\u003cli data-section-id=\"1ah5lkw\" data-start=\"3403\" data-end=\"3418\"\u003eCulture media\u003c\/li\u003e\n\u003cli data-section-id=\"1cxph7i\" data-start=\"3419\" data-end=\"3433\"\u003eRubber items\u003c\/li\u003e\n\u003cli data-section-id=\"dld93o\" data-start=\"3434\" data-end=\"3454\"\u003eLaboratory liquids\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3456\" data-end=\"3459\"\u003e\n\u003ch1 data-section-id=\"1qk0eh9\" data-start=\"3461\" data-end=\"3484\"\u003eAvailable Variants\u003c\/h1\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3486\" data-end=\"3629\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3486\" data-end=\"3506\"\u003e\n\u003ctr data-start=\"3486\" data-end=\"3506\"\u003e\n\u003cth data-start=\"3486\" data-end=\"3494\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eModel\u003c\/th\u003e\n\u003cth data-start=\"3494\" data-end=\"3506\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eCapacity\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3529\" data-end=\"3629\"\u003e\n\u003ctr data-start=\"3529\" data-end=\"3561\"\u003e\n\u003ctd data-start=\"3529\" data-end=\"3544\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3531\" data-end=\"3543\"\u003eBKQ-Z50I\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3544\" data-end=\"3561\"\u003e\u003cstrong data-start=\"3546\" data-end=\"3559\"\u003e50 Litres\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3562\" data-end=\"3594\"\u003e\n\u003ctd data-start=\"3562\" data-end=\"3577\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3564\" data-end=\"3576\"\u003eBKQ-Z75I\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3577\" data-end=\"3594\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3579\" data-end=\"3592\"\u003e75 Litres\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3595\" data-end=\"3629\"\u003e\n\u003ctd data-start=\"3595\" data-end=\"3611\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3597\" data-end=\"3610\"\u003eBKQ-Z100I\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3611\" data-end=\"3629\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3613\" data-end=\"3627\"\u003e100 Litres\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"3631\" data-end=\"3634\"\u003e\n\u003ch1 data-section-id=\"g1cszw\" data-start=\"3636\" data-end=\"3665\"\u003eTechnical Specifications\u003c\/h1\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3667\" data-end=\"4689\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3667\" data-end=\"3718\"\u003e\n\u003ctr data-start=\"3667\" data-end=\"3718\"\u003e\n\u003cth data-start=\"3667\" data-end=\"3683\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"3683\" data-end=\"3694\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eBKQ-Z50I\u003c\/th\u003e\n\u003cth data-start=\"3694\" data-end=\"3705\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eBKQ-Z75I\u003c\/th\u003e\n\u003cth data-start=\"3705\" data-end=\"3718\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eBKQ-Z100I\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3740\" data-end=\"4689\"\u003e\n\u003ctr data-start=\"3740\" data-end=\"3789\"\u003e\n\u003ctd data-start=\"3740\" data-end=\"3751\" data-col-size=\"sm\"\u003eCapacity\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3751\" data-end=\"3763\"\u003e50 Litres\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3763\" data-end=\"3775\"\u003e75 Litres\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3775\" data-end=\"3789\"\u003e100 Litres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3790\" data-end=\"3843\"\u003e\n\u003ctd data-start=\"3790\" data-end=\"3812\" data-col-size=\"sm\"\u003eSterilisation Class\u003c\/td\u003e\n\u003ctd data-start=\"3812\" data-end=\"3822\" data-col-size=\"sm\"\u003eClass B\u003c\/td\u003e\n\u003ctd data-start=\"3822\" data-end=\"3832\" data-col-size=\"sm\"\u003eClass B\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3832\" data-end=\"3843\"\u003eClass B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3844\" data-end=\"3939\"\u003e\n\u003ctd data-start=\"3844\" data-end=\"3863\" data-col-size=\"sm\"\u003eChamber Material\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3863\" data-end=\"3888\"\u003eSUS304 Stainless Steel\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3888\" data-end=\"3913\"\u003eSUS304 Stainless Steel\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3913\" data-end=\"3939\"\u003eSUS304 Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3940\" data-end=\"4004\"\u003e\n\u003ctd data-start=\"3940\" data-end=\"3955\" data-col-size=\"sm\"\u003eChamber Size\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3955\" data-end=\"3971\"\u003eØ385 × 515 mm\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3971\" data-end=\"3987\"\u003eØ385 × 715 mm\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3987\" data-end=\"4004\"\u003eØ385 × 875 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4005\" data-end=\"4070\"\u003e\n\u003ctd data-start=\"4005\" data-end=\"4027\" data-col-size=\"sm\"\u003eWorking Temperature\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4027\" data-end=\"4041\"\u003e105°C–136°C\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4041\" data-end=\"4055\"\u003e105°C–136°C\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4055\" data-end=\"4070\"\u003e105°C–136°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4071\" data-end=\"4124\"\u003e\n\u003ctd data-start=\"4071\" data-end=\"4090\" data-col-size=\"sm\"\u003eWorking Pressure\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4090\" data-end=\"4101\"\u003e0.23 MPa\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4101\" data-end=\"4112\"\u003e0.23 MPa\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4112\" data-end=\"4124\"\u003e0.23 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4125\" data-end=\"4179\"\u003e\n\u003ctd data-start=\"4125\" data-end=\"4145\" data-col-size=\"sm\"\u003eDesigned Pressure\u003c\/td\u003e\n\u003ctd data-start=\"4145\" data-end=\"4156\" data-col-size=\"sm\"\u003e0.28 MPa\u003c\/td\u003e\n\u003ctd data-start=\"4156\" data-end=\"4167\" data-col-size=\"sm\"\u003e0.28 MPa\u003c\/td\u003e\n\u003ctd data-start=\"4167\" data-end=\"4179\" data-col-size=\"sm\"\u003e0.28 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4180\" data-end=\"4228\"\u003e\n\u003ctd data-start=\"4180\" data-end=\"4203\" data-col-size=\"sm\"\u003eDesigned Temperature\u003c\/td\u003e\n\u003ctd data-start=\"4203\" data-end=\"4211\" data-col-size=\"sm\"\u003e150°C\u003c\/td\u003e\n\u003ctd data-start=\"4211\" data-end=\"4219\" data-col-size=\"sm\"\u003e150°C\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4219\" data-end=\"4228\"\u003e150°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4229\" data-end=\"4258\"\u003e\n\u003ctd data-start=\"4229\" data-end=\"4239\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"4239\" data-end=\"4245\" data-col-size=\"sm\"\u003eLED\u003c\/td\u003e\n\u003ctd data-start=\"4245\" data-end=\"4251\" data-col-size=\"sm\"\u003eLED\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4251\" data-end=\"4258\"\u003eLED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4259\" data-end=\"4316\"\u003e\n\u003ctd data-start=\"4259\" data-end=\"4291\" data-col-size=\"sm\"\u003eTemperature Display Precision\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4291\" data-end=\"4299\"\u003e0.1°C\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4299\" data-end=\"4307\"\u003e0.1°C\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4307\" data-end=\"4316\"\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4317\" data-end=\"4386\"\u003e\n\u003ctd data-start=\"4317\" data-end=\"4334\" data-col-size=\"sm\"\u003eControl System\u003c\/td\u003e\n\u003ctd data-start=\"4334\" data-end=\"4351\" data-col-size=\"sm\"\u003eMicroprocessor\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4351\" data-end=\"4368\"\u003eMicroprocessor\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4368\" data-end=\"4386\"\u003eMicroprocessor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4387\" data-end=\"4482\"\u003e\n\u003ctd data-start=\"4387\" data-end=\"4406\" data-col-size=\"sm\"\u003eChamber Material\u003c\/td\u003e\n\u003ctd data-start=\"4406\" data-end=\"4431\" data-col-size=\"sm\"\u003eSUS304 Stainless Steel\u003c\/td\u003e\n\u003ctd data-start=\"4431\" data-end=\"4456\" data-col-size=\"sm\"\u003eSUS304 Stainless Steel\u003c\/td\u003e\n\u003ctd data-start=\"4456\" data-end=\"4482\" data-col-size=\"sm\"\u003eSUS304 Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4483\" data-end=\"4542\"\u003e\n\u003ctd data-start=\"4483\" data-end=\"4506\" data-col-size=\"sm\"\u003eBasket Configuration\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4506\" data-end=\"4517\"\u003e1 Basket\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4517\" data-end=\"4529\"\u003e2 Baskets\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4529\" data-end=\"4542\"\u003e2 Baskets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4543\" data-end=\"4587\"\u003e\n\u003ctd data-start=\"4543\" data-end=\"4553\" data-col-size=\"sm\"\u003ePrinter\u003c\/td\u003e\n\u003ctd data-start=\"4553\" data-end=\"4564\" data-col-size=\"sm\"\u003eOptional\u003c\/td\u003e\n\u003ctd data-start=\"4564\" data-end=\"4575\" data-col-size=\"sm\"\u003eOptional\u003c\/td\u003e\n\u003ctd data-start=\"4575\" data-end=\"4587\" data-col-size=\"sm\"\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4588\" data-end=\"4630\"\u003e\n\u003ctd data-start=\"4588\" data-end=\"4602\" data-col-size=\"sm\"\u003eNoise Level\u003c\/td\u003e\n\u003ctd data-start=\"4602\" data-end=\"4611\" data-col-size=\"sm\"\u003e≤65 dB\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4611\" data-end=\"4620\"\u003e≤65 dB\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4620\" data-end=\"4630\"\u003e≤65 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4631\" data-end=\"4689\"\u003e\n\u003ctd data-start=\"4631\" data-end=\"4646\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4646\" data-end=\"4660\"\u003e220–240V AC\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4660\" data-end=\"4674\"\u003e220–240V AC\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4674\" data-end=\"4689\"\u003e220–240V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"4691\" data-end=\"4694\"\u003e\n\u003ch1 data-section-id=\"ohxjof\" data-start=\"4696\" data-end=\"4727\"\u003eStandards \u0026amp; Certification\u003c\/h1\u003e\n\u003cul data-start=\"4729\" data-end=\"4839\"\u003e\n\u003cli data-section-id=\"k988nn\" data-start=\"4729\" data-end=\"4759\"\u003eBIOBASE Manufactured Product\u003c\/li\u003e\n\u003cli data-section-id=\"dwg9k\" data-start=\"4760\" data-end=\"4789\"\u003eClass B Steam Sterilisation\u003c\/li\u003e\n\u003cli data-section-id=\"13u47xl\" data-start=\"4790\" data-end=\"4804\"\u003eCE Certified\u003c\/li\u003e\n\u003cli data-section-id=\"vzlut2\" data-start=\"4805\" data-end=\"4839\"\u003eISO 13485 Certified Manufacturer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4841\" data-end=\"4844\"\u003e\n\u003ch1 data-section-id=\"niky1a\" data-start=\"4846\" data-end=\"4867\"\u003eWhat's Included\u003c\/h1\u003e\n\u003cul data-start=\"4869\" data-end=\"4981\"\u003e\n\u003cli data-section-id=\"g2nhi3\" data-start=\"4869\" data-end=\"4911\"\u003eBIOBASE Class B Vertical Steam Autoclave\u003c\/li\u003e\n\u003cli data-section-id=\"14u4gm9\" data-start=\"4912\" data-end=\"4953\"\u003eStainless steel sterilisation basket(s)\u003c\/li\u003e\n\u003cli data-section-id=\"mv2eu6\" data-start=\"4954\" data-end=\"4967\"\u003ePower cable\u003c\/li\u003e\n\u003cli data-section-id=\"hg43yb\" data-start=\"4968\" data-end=\"4981\"\u003eUser manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4983\" data-end=\"5007\"\u003e\u003cstrong data-start=\"4983\" data-end=\"5007\"\u003eOptional Accessories\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"5009\" data-end=\"5081\"\u003e\n\u003cli data-section-id=\"1forz9l\" data-start=\"5009\" data-end=\"5035\"\u003eBuilt-in thermal printer\u003c\/li\u003e\n\u003cli data-section-id=\"ras96t\" data-start=\"5036\" data-end=\"5060\"\u003eStainless steel bucket\u003c\/li\u003e\n\u003cli data-section-id=\"qmctpa\" data-start=\"5061\" data-end=\"5081\"\u003eMesh bottom basket\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"5083\" data-end=\"5086\"\u003e\n\u003ch1 data-section-id=\"4fmhzf\" data-start=\"5088\" data-end=\"5113\"\u003eWarranty \u0026amp; Shipping\u003c\/h1\u003e\n\u003ch3 data-section-id=\"16fiq7\" data-start=\"5115\" data-end=\"5151\"\u003e12-Month Manufacturer's Warranty\u003c\/h3\u003e\n\u003cp data-start=\"5153\" data-end=\"5262\"\u003eAustralian customer support is provided for all BIOBASE autoclaves supplied by Australian Mycology Equipment.\u003c\/p\u003e\n\u003ch3 data-section-id=\"130532u\" data-start=\"5264\" data-end=\"5296\"\u003eFREE Australia-Wide Shipping\u003c\/h3\u003e\n\u003cp data-start=\"5298\" data-end=\"5357\"\u003eFREE Australia-wide shipping is included with this product.\u003c\/p\u003e\n\u003cp data-start=\"5359\" data-end=\"5540\"\u003eFor deliveries to remote, regional or difficult-to-access locations, additional freight charges may apply. If required, we will contact you with a freight quotation before dispatch.\u003c\/p\u003e\n\u003chr data-start=\"5542\" data-end=\"5545\"\u003e\n\u003ch1 data-section-id=\"p538tw\" data-start=\"5547\" data-end=\"5564\"\u003ePlease Note\u003c\/h1\u003e\n\u003cp data-start=\"5566\" data-end=\"5781\"\u003eThe BIOBASE BKQ-Z Series is designed for sterilising wrapped and unwrapped instruments, laboratory glassware, dressings, rubber items, culture media, liquids and other compatible heat-resistant laboratory materials.\u003c\/p\u003e\n\u003cp data-start=\"5783\" data-end=\"6073\"\u003eThe spring-assisted quick-opening lid makes opening and closing the chamber smooth and effortless while helping reduce operator fatigue. The enclosed lid design also helps minimise accidental contact with hot metal surfaces after sterilisation, improving operator safety during routine use.\u003c\/p\u003e\n\u003cp data-start=\"6075\" data-end=\"6222\"\u003eAn optional built-in thermal printer is available for recording sterilisation cycle data to support laboratory quality assurance and documentation.\u003c\/p\u003e\n\u003cp data-start=\"6224\" data-end=\"6372\"\u003eUse only distilled or demineralised water. Damage caused by tap water, bore water, rainwater or other untreated water is not covered under warranty.\u003c\/p\u003e","brand":"Australian Mycology Equipment","offers":[{"title":"BKQ-Z50L 50 Litre","offer_id":51930582909216,"sku":null,"price":4750.0,"currency_code":"AUD","in_stock":true},{"title":"BKQ-Z75L 75 Litre","offer_id":51930582941984,"sku":null,"price":4950.0,"currency_code":"AUD","in_stock":true},{"title":"BKQ-Z100L Litre","offer_id":51930582974752,"sku":null,"price":5459.0,"currency_code":"AUD","in_stock":true},{"title":"Optiona Thermal Printer","offer_id":51930585432352,"sku":null,"price":5950.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0806\/0721\/5904\/files\/BKQ-Z100I.jpg?v=1782913659"},{"product_id":"scienfocus-horizontal-laminar-flow-cabinet-h14-hepa-filter-800-1740mm","title":"ScienFocus Horizontal Laminar Flow Cabinet | H14 HEPA Filter | 800–1740mm","description":"\u003cp data-start=\"49\" data-end=\"388\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"53\" data-end=\"102\"\u003eScienFocus C5 Horizontal Laminar Flow Cabinet\u003c\/strong\u003e is a professional clean air workstation designed for mycology laboratories, universities, research facilities, biotechnology laboratories, pharmaceutical manufacturing, food testing laboratories and other contamination-sensitive environments requiring ISO Class 5 clean air conditions.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"390\" data-end=\"759\"\u003eAvailable in \u003cstrong data-start=\"403\" data-end=\"472\"\u003eC5-PD-W800, C5-PD-W1000, C5-PD-W1200, C5-PD-W1500 and C5-PD-W1740\u003c\/strong\u003e models, the C5 Series delivers a continuous stream of H14 HEPA filtered air horizontally across the work surface, creating a clean working environment for agar work, tissue culture, grain spawn preparation, microbiology, electronics assembly and other precision laboratory applications.\u003c\/p\u003e\n\u003cp data-start=\"761\" data-end=\"1120\"\u003eUnlike many traditional laboratory cabinets, the ScienFocus C5 Series is supplied \u003cstrong data-start=\"843\" data-end=\"858\"\u003eflat packed\u003c\/strong\u003e, significantly reducing shipping costs while helping minimise the risk of transport damage during freight. Once assembled, it provides the same professional laboratory performance while offering a more economical shipping solution than fully assembled cabinets.\u003c\/p\u003e\n\u003cp data-start=\"1122\" data-end=\"1439\"\u003eManufactured with a powder-coated steel cabinet, a SUS304 stainless steel work surface, tempered glass side panels, integrated LED lighting and a high-performance centrifugal blower, the C5 Series combines durability, excellent visibility and dependable long-term performance for professional laboratory environments.\u003c\/p\u003e\n\u003chr data-start=\"1441\" data-end=\"1444\"\u003e\n\u003ch1 data-section-id=\"1fah8gx\" data-start=\"1446\" data-end=\"1456\"\u003eFeatures\u003c\/h1\u003e\n\u003cul data-start=\"1458\" data-end=\"2128\"\u003e\n\u003cli data-section-id=\"1mcp1cr\" data-start=\"1458\" data-end=\"1480\"\u003eScienFocus C5 Series\u003c\/li\u003e\n\u003cli data-section-id=\"1b80tyh\" data-start=\"1481\" data-end=\"1566\"\u003eAvailable in C5-PD-W800, C5-PD-W1000, C5-PD-W1200, C5-PD-W1500 \u0026amp; C5-PD-W1740 models\u003c\/li\u003e\n\u003cli data-section-id=\"1lw2of5\" data-start=\"1567\" data-end=\"1608\"\u003eProfessional horizontal laminar airflow\u003c\/li\u003e\n\u003cli data-section-id=\"baj8ax\" data-start=\"1609\" data-end=\"1674\"\u003eFlat-packed design for safer transport and lower shipping costs\u003c\/li\u003e\n\u003cli data-section-id=\"19lsgp9\" data-start=\"1675\" data-end=\"1721\"\u003eH14 HEPA filter (99.995% efficiency @ 0.3μm)\u003c\/li\u003e\n\u003cli data-section-id=\"1pbf57w\" data-start=\"1722\" data-end=\"1757\"\u003eISO Class 5 clean air environment\u003c\/li\u003e\n\u003cli data-section-id=\"u6lcdo\" data-start=\"1758\" data-end=\"1795\"\u003eHigh-performance centrifugal blower\u003c\/li\u003e\n\u003cli data-section-id=\"1g5ri9m\" data-start=\"1796\" data-end=\"1824\"\u003eUniform horizontal airflow\u003c\/li\u003e\n\u003cli data-section-id=\"1t2cp25\" data-start=\"1825\" data-end=\"1862\"\u003eSUS304 stainless steel work surface\u003c\/li\u003e\n\u003cli data-section-id=\"hdo0hn\" data-start=\"1863\" data-end=\"1892\"\u003ePowder-coated steel cabinet\u003c\/li\u003e\n\u003cli data-section-id=\"irfsxy\" data-start=\"1893\" data-end=\"1921\"\u003eTempered glass side panels\u003c\/li\u003e\n\u003cli data-section-id=\"1regs6n\" data-start=\"1922\" data-end=\"1942\"\u003eAcrylic front sash\u003c\/li\u003e\n\u003cli data-section-id=\"45gx70\" data-start=\"1943\" data-end=\"1968\"\u003eIntegrated LED lighting\u003c\/li\u003e\n\u003cli data-section-id=\"ftvr43\" data-start=\"1969\" data-end=\"1998\"\u003eThree-speed airflow control\u003c\/li\u003e\n\u003cli data-section-id=\"d1z8f9\" data-start=\"1999\" data-end=\"2020\"\u003eWashable pre-filter\u003c\/li\u003e\n\u003cli data-section-id=\"1mh5liv\" data-start=\"2021\" data-end=\"2042\"\u003eLow noise operation\u003c\/li\u003e\n\u003cli data-section-id=\"1tszg1v\" data-start=\"2043\" data-end=\"2073\"\u003eLarge unobstructed work area\u003c\/li\u003e\n\u003cli data-section-id=\"1qdhcrf\" data-start=\"2074\" data-end=\"2099\"\u003eEasy filter maintenance\u003c\/li\u003e\n\u003cli data-section-id=\"ur2hz8\" data-start=\"2100\" data-end=\"2128\"\u003e240V Australian compatible\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2130\" data-end=\"2133\"\u003e\n\u003ch1 data-section-id=\"od9i1k\" data-start=\"2135\" data-end=\"2146\"\u003eIdeal For\u003c\/h1\u003e\n\u003cul data-start=\"2148\" data-end=\"2453\"\u003e\n\u003cli data-section-id=\"knhpoo\" data-start=\"2148\" data-end=\"2171\"\u003eMycology laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1dbstkl\" data-start=\"2172\" data-end=\"2197\"\u003eMushroom tissue culture\u003c\/li\u003e\n\u003cli data-section-id=\"uep2qw\" data-start=\"2198\" data-end=\"2222\"\u003eAgar plate preparation\u003c\/li\u003e\n\u003cli data-section-id=\"1hsnfj7\" data-start=\"2223\" data-end=\"2247\"\u003eGrain spawn production\u003c\/li\u003e\n\u003cli data-section-id=\"tuv45w\" data-start=\"2248\" data-end=\"2271\"\u003eResearch laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"10gwr6y\" data-start=\"2272\" data-end=\"2286\"\u003eUniversities\u003c\/li\u003e\n\u003cli data-section-id=\"1or0uhb\" data-start=\"2287\" data-end=\"2315\"\u003eBiotechnology laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"60wbl6\" data-start=\"2316\" data-end=\"2345\"\u003ePharmaceutical laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1pcjfkp\" data-start=\"2346\" data-end=\"2373\"\u003eFood testing laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"l94mk0\" data-start=\"2374\" data-end=\"2399\"\u003eVeterinary laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1qmolaf\" data-start=\"2400\" data-end=\"2422\"\u003eElectronics assembly\u003c\/li\u003e\n\u003cli data-section-id=\"14jhzbb\" data-start=\"2423\" data-end=\"2453\"\u003eQuality control laboratories\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2455\" data-end=\"2458\"\u003e\n\u003ch1 data-section-id=\"1a2z97\" data-start=\"2460\" data-end=\"2480\"\u003eAvailable Variants\u003c\/h1\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2482\" data-end=\"2665\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2482\" data-end=\"2507\"\u003e\n\u003ctr data-start=\"2482\" data-end=\"2507\"\u003e\n\u003cth data-start=\"2482\" data-end=\"2490\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eModel\u003c\/th\u003e\n\u003cth data-start=\"2490\" data-end=\"2507\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eWorking Width\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2543\" data-end=\"2665\"\u003e\n\u003ctr data-start=\"2543\" data-end=\"2565\"\u003e\n\u003ctd data-start=\"2543\" data-end=\"2556\" data-col-size=\"sm\"\u003eC5-PD-W800\u003c\/td\u003e\n\u003ctd data-start=\"2556\" data-end=\"2565\" data-col-size=\"sm\"\u003e800mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2566\" data-end=\"2590\"\u003e\n\u003ctd data-start=\"2566\" data-end=\"2580\" data-col-size=\"sm\"\u003eC5-PD-W1000\u003c\/td\u003e\n\u003ctd data-start=\"2580\" data-end=\"2590\" data-col-size=\"sm\"\u003e1000mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2591\" data-end=\"2615\"\u003e\n\u003ctd data-start=\"2591\" data-end=\"2605\" data-col-size=\"sm\"\u003eC5-PD-W1200\u003c\/td\u003e\n\u003ctd data-start=\"2605\" data-end=\"2615\" data-col-size=\"sm\"\u003e1200mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2616\" data-end=\"2640\"\u003e\n\u003ctd data-start=\"2616\" data-end=\"2630\" data-col-size=\"sm\"\u003eC5-PD-W1500\u003c\/td\u003e\n\u003ctd data-start=\"2630\" data-end=\"2640\" data-col-size=\"sm\"\u003e1500mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2641\" data-end=\"2665\"\u003e\n\u003ctd data-start=\"2641\" data-end=\"2655\" data-col-size=\"sm\"\u003eC5-PD-W1740\u003c\/td\u003e\n\u003ctd data-start=\"2655\" data-end=\"2665\" data-col-size=\"sm\"\u003e1740mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"2667\" data-end=\"2670\"\u003e\n\u003ch1 data-section-id=\"zjxypn\" data-start=\"2672\" data-end=\"2698\"\u003eTechnical Specifications\u003c\/h1\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2700\" data-end=\"3367\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2700\" data-end=\"2729\"\u003e\n\u003ctr data-start=\"2700\" data-end=\"2729\"\u003e\n\u003cth data-start=\"2700\" data-end=\"2716\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2716\" data-end=\"2729\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eC5 Series\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2800\" data-end=\"3367\"\u003e\n\u003ctr data-start=\"2800\" data-end=\"2847\"\u003e\n\u003ctd data-start=\"2800\" data-end=\"2820\" data-col-size=\"sm\"\u003eAirflow Direction\u003c\/td\u003e\n\u003ctd data-start=\"2820\" data-end=\"2847\" data-col-size=\"sm\"\u003eHorizontal Laminar Flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2848\" data-end=\"2881\"\u003e\n\u003ctd data-start=\"2848\" data-end=\"2866\" data-col-size=\"sm\"\u003eAir Cleanliness\u003c\/td\u003e\n\u003ctd data-start=\"2866\" data-end=\"2881\" data-col-size=\"sm\"\u003eISO Class 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2882\" data-end=\"2909\"\u003e\n\u003ctd data-start=\"2882\" data-end=\"2902\" data-col-size=\"sm\"\u003eHEPA Filter Grade\u003c\/td\u003e\n\u003ctd data-start=\"2902\" data-end=\"2909\" data-col-size=\"sm\"\u003eH14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2910\" data-end=\"2954\"\u003e\n\u003ctd data-start=\"2910\" data-end=\"2935\" data-col-size=\"sm\"\u003eHEPA Filter Efficiency\u003c\/td\u003e\n\u003ctd data-start=\"2935\" data-end=\"2954\" data-col-size=\"sm\"\u003e99.995% @ 0.3μm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2955\" data-end=\"2997\"\u003e\n\u003ctd data-start=\"2955\" data-end=\"2978\" data-col-size=\"sm\"\u003eAverage Air Velocity\u003c\/td\u003e\n\u003ctd data-start=\"2978\" data-end=\"2997\" data-col-size=\"sm\"\u003e0.45 ± 0.05 m\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2998\" data-end=\"3039\"\u003e\n\u003ctd data-start=\"2998\" data-end=\"3013\" data-col-size=\"sm\"\u003eWork Surface\u003c\/td\u003e\n\u003ctd data-start=\"3013\" data-end=\"3039\" data-col-size=\"sm\"\u003eSUS304 Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3040\" data-end=\"3082\"\u003e\n\u003ctd data-start=\"3040\" data-end=\"3059\" data-col-size=\"sm\"\u003eCabinet Material\u003c\/td\u003e\n\u003ctd data-start=\"3059\" data-end=\"3082\" data-col-size=\"sm\"\u003ePowder-Coated Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3083\" data-end=\"3115\"\u003e\n\u003ctd data-start=\"3083\" data-end=\"3097\" data-col-size=\"sm\"\u003eSide Panels\u003c\/td\u003e\n\u003ctd data-start=\"3097\" data-end=\"3115\" data-col-size=\"sm\"\u003eTempered Glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3116\" data-end=\"3155\"\u003e\n\u003ctd data-start=\"3116\" data-end=\"3131\" data-col-size=\"sm\"\u003eFront Window\u003c\/td\u003e\n\u003ctd data-start=\"3131\" data-end=\"3155\" data-col-size=\"sm\"\u003eAcrylic Lift-Up Sash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3156\" data-end=\"3185\"\u003e\n\u003ctd data-start=\"3156\" data-end=\"3167\" data-col-size=\"sm\"\u003eLighting\u003c\/td\u003e\n\u003ctd data-start=\"3167\" data-end=\"3185\" data-col-size=\"sm\"\u003eIntegrated LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3186\" data-end=\"3214\"\u003e\n\u003ctd data-start=\"3186\" data-end=\"3195\" data-col-size=\"sm\"\u003eBlower\u003c\/td\u003e\n\u003ctd data-start=\"3195\" data-end=\"3214\" data-col-size=\"sm\"\u003eCentrifugal Fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3215\" data-end=\"3253\"\u003e\n\u003ctd data-start=\"3215\" data-end=\"3227\" data-col-size=\"sm\"\u003eFan Speed\u003c\/td\u003e\n\u003ctd data-start=\"3227\" data-end=\"3253\" data-col-size=\"sm\"\u003eThree-Speed Adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3254\" data-end=\"3279\"\u003e\n\u003ctd data-start=\"3254\" data-end=\"3267\" data-col-size=\"sm\"\u003ePre-Filter\u003c\/td\u003e\n\u003ctd data-start=\"3267\" data-end=\"3279\" data-col-size=\"sm\"\u003eWashable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3280\" data-end=\"3304\"\u003e\n\u003ctd data-start=\"3280\" data-end=\"3294\" data-col-size=\"sm\"\u003eNoise Level\u003c\/td\u003e\n\u003ctd data-start=\"3294\" data-end=\"3304\" data-col-size=\"sm\"\u003e≤65 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3305\" data-end=\"3335\"\u003e\n\u003ctd data-start=\"3305\" data-end=\"3320\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"3320\" data-end=\"3335\" data-col-size=\"sm\"\u003e220–240V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3336\" data-end=\"3367\"\u003e\n\u003ctd data-start=\"3336\" data-end=\"3360\" data-col-size=\"sm\"\u003eAustralian Compatible\u003c\/td\u003e\n\u003ctd data-start=\"3360\" data-end=\"3367\" data-col-size=\"sm\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch1 data-section-id=\"ese5zk\" data-start=\"3584\" data-end=\"3611\" class=\"PDq2pG_selectionAnchorContainer\"\u003eStandards \u0026amp; Certification\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3613\" data-end=\"3791\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3613\" data-end=\"3634\"\u003e\n\u003ctr data-start=\"3613\" data-end=\"3634\"\u003e\n\u003cth data-start=\"3613\" data-end=\"3624\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eStandard\u003c\/th\u003e\n\u003cth data-start=\"3624\" data-end=\"3634\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eStatus\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3683\" data-end=\"3791\"\u003e\n\u003ctr data-start=\"3683\" data-end=\"3712\"\u003e\n\u003ctd data-start=\"3683\" data-end=\"3698\" data-col-size=\"sm\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd data-start=\"3698\" data-end=\"3712\" data-col-size=\"sm\"\u003eScienFocus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3713\" data-end=\"3746\"\u003e\n\u003ctd data-start=\"3713\" data-end=\"3731\" data-col-size=\"sm\"\u003eAir Cleanliness\u003c\/td\u003e\n\u003ctd data-start=\"3731\" data-end=\"3746\" data-col-size=\"sm\"\u003eISO Class 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3747\" data-end=\"3768\"\u003e\n\u003ctd data-start=\"3747\" data-end=\"3761\" data-col-size=\"sm\"\u003eHEPA Filter\u003c\/td\u003e\n\u003ctd data-start=\"3761\" data-end=\"3768\" data-col-size=\"sm\"\u003eH14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3769\" data-end=\"3791\"\u003e\n\u003ctd data-start=\"3769\" data-end=\"3784\" data-col-size=\"sm\"\u003eCE Certified\u003c\/td\u003e\n\u003ctd data-start=\"3784\" data-end=\"3791\" data-col-size=\"sm\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"3793\" data-end=\"3796\"\u003e\n\u003ch1 data-section-id=\"1jxbixs\" data-start=\"3798\" data-end=\"3815\"\u003eWhat's Included\u003c\/h1\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3817\" data-end=\"4053\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3817\" data-end=\"3829\"\u003e\n\u003ctr data-start=\"3817\" data-end=\"3829\"\u003e\n\u003cth data-start=\"3817\" data-end=\"3829\" data-col-size=\"md\" class=\"last:pe-10\"\u003eIncluded\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3844\" data-end=\"4053\"\u003e\n\u003ctr data-start=\"3844\" data-end=\"3893\"\u003e\n\u003ctd data-start=\"3844\" data-end=\"3893\" data-col-size=\"md\"\u003eScienFocus C5 Horizontal Laminar Flow Cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3894\" data-end=\"3913\"\u003e\n\u003ctd data-start=\"3894\" data-end=\"3913\" data-col-size=\"md\"\u003eH14 HEPA Filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3914\" data-end=\"3937\"\u003e\n\u003ctd data-start=\"3914\" data-end=\"3937\" data-col-size=\"md\"\u003eWashable Pre-Filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3938\" data-end=\"3960\"\u003e\n\u003ctd data-start=\"3938\" data-end=\"3960\" data-col-size=\"md\"\u003eCentrifugal Blower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3961\" data-end=\"3984\"\u003e\n\u003ctd data-start=\"3961\" data-end=\"3984\" data-col-size=\"md\"\u003eLED Lighting System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3985\" data-end=\"4015\"\u003e\n\u003ctd data-start=\"3985\" data-end=\"4015\" data-col-size=\"md\"\u003eTempered Glass Side Panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4016\" data-end=\"4037\"\u003e\n\u003ctd data-start=\"4016\" data-end=\"4037\" data-col-size=\"md\"\u003eAssembly Hardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4038\" data-end=\"4053\"\u003e\n\u003ctd data-start=\"4038\" data-end=\"4053\" data-col-size=\"md\"\u003eUser Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"4055\" data-end=\"4058\"\u003e\n\u003ch1 data-section-id=\"yknlu6\" data-start=\"4060\" data-end=\"4082\"\u003eOptional Accessories\u003c\/h1\u003e\n\u003cul data-start=\"4084\" data-end=\"4198\"\u003e\n\u003cli data-section-id=\"5k553b\" data-start=\"4084\" data-end=\"4113\"\u003eReplacement H14 HEPA Filter\u003c\/li\u003e\n\u003cli data-section-id=\"1q8danw\" data-start=\"4114\" data-end=\"4138\"\u003eReplacement Pre-Filter\u003c\/li\u003e\n\u003cli data-section-id=\"cpsh61\" data-start=\"4139\" data-end=\"4171\"\u003eReplacement Centrifugal Blower\u003c\/li\u003e\n\u003cli data-section-id=\"1r0bbet\" data-start=\"4172\" data-end=\"4198\"\u003eReplacement LED Lighting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4200\" data-end=\"4203\"\u003e\n\u003ch1 data-section-id=\"1jol37q\" data-start=\"4205\" data-end=\"4226\"\u003eWarranty \u0026amp; Shipping\u003c\/h1\u003e\n\u003cp data-start=\"4228\" data-end=\"4264\"\u003e\u003cstrong data-start=\"4228\" data-end=\"4264\"\u003e12-Month Manufacturer's Warranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4266\" data-end=\"4389\"\u003eAustralian customer support is provided for all ScienFocus laminar flow cabinets supplied by Australian Mycology Equipment.\u003c\/p\u003e\n\u003ch2 data-section-id=\"eibc6t\" data-start=\"4391\" data-end=\"4422\"\u003eFREE Australia-Wide Shipping\u003c\/h2\u003e\n\u003cp data-start=\"4424\" data-end=\"4563\"\u003eFREE shipping is included to most Australian metro and regional locations, generally within \u003cstrong data-start=\"4516\" data-end=\"4562\"\u003e250 km of Australia's major capital cities\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"4565\" data-end=\"4708\"\u003eThese cabinets are imported to order and have an \u003cstrong data-start=\"4614\" data-end=\"4669\"\u003eestimated delivery time of approximately 35–40 days\u003c\/strong\u003e from the date your order is confirmed.\u003c\/p\u003e\n\u003cp data-start=\"4710\" data-end=\"4970\"\u003eIf your delivery address falls outside our standard free shipping area, including remote, rural or difficult-to-access locations, we will contact you with a freight quotation before dispatch. No additional freight charges will be applied without your approval.\u003c\/p\u003e\n\u003chr data-start=\"4972\" data-end=\"4975\"\u003e\n\u003ch1 data-section-id=\"1vv921k\" data-start=\"4977\" data-end=\"4990\"\u003ePlease Note\u003c\/h1\u003e\n\u003cp data-start=\"4992\" data-end=\"5207\"\u003eThe \u003cstrong data-start=\"4996\" data-end=\"5020\"\u003eScienFocus C5 Series\u003c\/strong\u003e is supplied \u003cstrong data-start=\"5033\" data-end=\"5048\"\u003eflat packed\u003c\/strong\u003e to reduce freight costs and minimise the risk of transport damage during shipping. Assembly is straightforward using the supplied components and instructions.\u003c\/p\u003e\n\u003cp data-start=\"5209\" data-end=\"5529\"\u003eHorizontal laminar flow cabinets are designed to provide a continuous stream of HEPA-filtered air across the work surface, creating an ISO Class 5 clean working environment for contamination-sensitive procedures including agar work, tissue culture, microbiology, grain spawn preparation and laboratory media preparation.\u003c\/p\u003e\n\u003cp data-start=\"5531\" data-end=\"5874\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eThese cabinets are designed to \u003cstrong data-start=\"5562\" data-end=\"5583\"\u003eprotect your work\u003c\/strong\u003e by supplying clean, HEPA-filtered air across the workspace. They are \u003cstrong data-start=\"5653\" data-end=\"5687\"\u003enot biological safety cabinets\u003c\/strong\u003e and are \u003cstrong data-start=\"5696\" data-end=\"5794\"\u003enot intended for handling hazardous biological agents, infectious materials or toxic chemicals\u003c\/strong\u003e. Use only for clean laboratory procedures where product protection is required.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003chr data-end=\"3534\" data-start=\"3531\"\u003e","brand":"Australian Mycology Equipment","offers":[{"title":"C5-PD-W800","offer_id":51967825477920,"sku":null,"price":2395.0,"currency_code":"AUD","in_stock":true},{"title":"C5-PD-W1000","offer_id":51967825510688,"sku":null,"price":2695.0,"currency_code":"AUD","in_stock":true},{"title":"C5-PD-W1200","offer_id":51967825543456,"sku":null,"price":2995.0,"currency_code":"AUD","in_stock":true},{"title":"C5-PD-W1500","offer_id":51967825576224,"sku":null,"price":3395.0,"currency_code":"AUD","in_stock":true},{"title":"C5-PD-W1740","offer_id":51967825608992,"sku":null,"price":3695.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0806\/0721\/5904\/files\/HorizontalFlowHood.jpg?v=1783694391"},{"product_id":"scienfocus-c8-desktop-vertical-laminar-flow-cabinet","title":"ScienFocus C8 Desktop Vertical Laminar Flow Cabinet","description":"\u003cp data-start=\"164\" data-end=\"509\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"168\" data-end=\"223\"\u003eScienFocus C8 Desktop Vertical Laminar Flow Cabinet\u003c\/strong\u003e is a professional clean air workstation designed for mycology laboratories, universities, research facilities, biotechnology laboratories, pharmaceutical manufacturing, food testing laboratories and other contamination-sensitive environments requiring ISO Class 5 clean air conditions.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"511\" data-end=\"857\"\u003eAvailable in \u003cstrong data-start=\"524\" data-end=\"591\"\u003eC8-BT-W500, C8-BT-W650, C8-BT-W800, C8-BT-W1000 and C8-BT-W1200\u003c\/strong\u003e models, the C8 Series delivers H14 HEPA filtered air vertically across the work surface, creating a clean working environment for agar work, tissue culture, grain spawn preparation, microbiology, laboratory media preparation and other sterile laboratory procedures.\u003c\/p\u003e\n\u003cp data-start=\"859\" data-end=\"1180\"\u003eManufactured with a powder-coated steel cabinet, SUS304 stainless steel work surface, clear acrylic side panels, integrated LED lighting and a high-performance centrifugal blower, the C8 Series combines excellent visibility, reliable performance and a compact footprint suitable for laboratories with limited bench space.\u003c\/p\u003e\n\u003cp data-start=\"1182\" data-end=\"1347\"\u003eSupplied fully assembled, the C8 Series is ready for installation. Simply position the cabinet on a suitable laboratory bench, connect the power and begin operation.\u003c\/p\u003e\n\u003chr data-start=\"1349\" data-end=\"1352\"\u003e\n\u003ch1 data-section-id=\"1fah8gx\" data-start=\"1354\" data-end=\"1364\"\u003eFeatures\u003c\/h1\u003e\n\u003cul data-start=\"1366\" data-end=\"1914\"\u003e\n\u003cli data-section-id=\"1n0cysk\" data-start=\"1366\" data-end=\"1396\"\u003eScienFocus C8 Desktop Series\u003c\/li\u003e\n\u003cli data-section-id=\"16vqcw6\" data-start=\"1397\" data-end=\"1480\"\u003eAvailable in C8-BT-W500, C8-BT-W650, C8-BT-W800, C8-BT-W1000 \u0026amp; C8-BT-W1200 models\u003c\/li\u003e\n\u003cli data-section-id=\"6w96j1\" data-start=\"1481\" data-end=\"1520\"\u003eProfessional vertical laminar airflow\u003c\/li\u003e\n\u003cli data-section-id=\"ub9zm7\" data-start=\"1521\" data-end=\"1545\"\u003eCompact desktop design\u003c\/li\u003e\n\u003cli data-section-id=\"19lsgp9\" data-start=\"1546\" data-end=\"1592\"\u003eH14 HEPA filter (99.995% efficiency @ 0.3μm)\u003c\/li\u003e\n\u003cli data-section-id=\"1pbf57w\" data-start=\"1593\" data-end=\"1628\"\u003eISO Class 5 clean air environment\u003c\/li\u003e\n\u003cli data-section-id=\"u6lcdo\" data-start=\"1629\" data-end=\"1666\"\u003eHigh-performance centrifugal blower\u003c\/li\u003e\n\u003cli data-section-id=\"k9uopi\" data-start=\"1667\" data-end=\"1693\"\u003eUniform vertical airflow\u003c\/li\u003e\n\u003cli data-section-id=\"1t2cp25\" data-start=\"1694\" data-end=\"1731\"\u003eSUS304 stainless steel work surface\u003c\/li\u003e\n\u003cli data-section-id=\"hdo0hn\" data-start=\"1732\" data-end=\"1761\"\u003ePowder-coated steel cabinet\u003c\/li\u003e\n\u003cli data-section-id=\"up0pr4\" data-start=\"1762\" data-end=\"1789\"\u003eClear acrylic side panels\u003c\/li\u003e\n\u003cli data-section-id=\"45gx70\" data-start=\"1790\" data-end=\"1815\"\u003eIntegrated LED lighting\u003c\/li\u003e\n\u003cli data-section-id=\"d1z8f9\" data-start=\"1816\" data-end=\"1837\"\u003eWashable pre-filter\u003c\/li\u003e\n\u003cli data-section-id=\"1mh5liv\" data-start=\"1838\" data-end=\"1859\"\u003eLow noise operation\u003c\/li\u003e\n\u003cli data-section-id=\"1qdhcrf\" data-start=\"1860\" data-end=\"1885\"\u003eEasy filter maintenance\u003c\/li\u003e\n\u003cli data-section-id=\"ur2hz8\" data-start=\"1886\" data-end=\"1914\"\u003e240V Australian compatible\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1916\" data-end=\"1919\"\u003e\n\u003ch1 data-section-id=\"od9i1k\" data-start=\"1921\" data-end=\"1932\"\u003eIdeal For\u003c\/h1\u003e\n\u003cul data-start=\"1934\" data-end=\"2239\"\u003e\n\u003cli data-section-id=\"knhpoo\" data-start=\"1934\" data-end=\"1957\"\u003eMycology laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1dbstkl\" data-start=\"1958\" data-end=\"1983\"\u003eMushroom tissue culture\u003c\/li\u003e\n\u003cli data-section-id=\"uep2qw\" data-start=\"1984\" data-end=\"2008\"\u003eAgar plate preparation\u003c\/li\u003e\n\u003cli data-section-id=\"1hsnfj7\" data-start=\"2009\" data-end=\"2033\"\u003eGrain spawn production\u003c\/li\u003e\n\u003cli data-section-id=\"tuv45w\" data-start=\"2034\" data-end=\"2057\"\u003eResearch laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"10gwr6y\" data-start=\"2058\" data-end=\"2072\"\u003eUniversities\u003c\/li\u003e\n\u003cli data-section-id=\"1or0uhb\" data-start=\"2073\" data-end=\"2101\"\u003eBiotechnology laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"60wbl6\" data-start=\"2102\" data-end=\"2131\"\u003ePharmaceutical laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1pcjfkp\" data-start=\"2132\" data-end=\"2159\"\u003eFood testing laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"l94mk0\" data-start=\"2160\" data-end=\"2185\"\u003eVeterinary laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1qmolaf\" data-start=\"2186\" data-end=\"2208\"\u003eElectronics assembly\u003c\/li\u003e\n\u003cli data-section-id=\"14jhzbb\" data-start=\"2209\" data-end=\"2239\"\u003eQuality control laboratories\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2241\" data-end=\"2244\"\u003e\n\u003ch1 data-section-id=\"1a2z97\" data-start=\"2246\" data-end=\"2266\"\u003eAvailable Variants\u003c\/h1\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2268\" data-end=\"2447\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2268\" data-end=\"2293\"\u003e\n\u003ctr data-start=\"2268\" data-end=\"2293\"\u003e\n\u003cth data-start=\"2268\" data-end=\"2276\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eModel\u003c\/th\u003e\n\u003cth data-start=\"2276\" data-end=\"2293\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eWorking Width\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2329\" data-end=\"2447\"\u003e\n\u003ctr data-start=\"2329\" data-end=\"2351\"\u003e\n\u003ctd data-start=\"2329\" data-end=\"2342\" data-col-size=\"sm\"\u003eC8-BT-W500\u003c\/td\u003e\n\u003ctd data-start=\"2342\" data-end=\"2351\" data-col-size=\"sm\"\u003e500mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2352\" data-end=\"2374\"\u003e\n\u003ctd data-start=\"2352\" data-end=\"2365\" data-col-size=\"sm\"\u003eC8-BT-W650\u003c\/td\u003e\n\u003ctd data-start=\"2365\" data-end=\"2374\" data-col-size=\"sm\"\u003e650mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2375\" data-end=\"2397\"\u003e\n\u003ctd data-start=\"2375\" data-end=\"2388\" data-col-size=\"sm\"\u003eC8-BT-W800\u003c\/td\u003e\n\u003ctd data-start=\"2388\" data-end=\"2397\" data-col-size=\"sm\"\u003e800mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2398\" data-end=\"2422\"\u003e\n\u003ctd data-start=\"2398\" data-end=\"2412\" data-col-size=\"sm\"\u003eC8-BT-W1000\u003c\/td\u003e\n\u003ctd data-start=\"2412\" data-end=\"2422\" data-col-size=\"sm\"\u003e1000mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2423\" data-end=\"2447\"\u003e\n\u003ctd data-start=\"2423\" data-end=\"2437\" data-col-size=\"sm\"\u003eC8-BT-W1200\u003c\/td\u003e\n\u003ctd data-start=\"2437\" data-end=\"2447\" data-col-size=\"sm\"\u003e1200mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"2449\" data-end=\"2452\"\u003e\n\u003ch1 data-section-id=\"zjxypn\" data-start=\"2454\" data-end=\"2480\"\u003eTechnical Specifications\u003c\/h1\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2482\" data-end=\"3082\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2482\" data-end=\"2519\"\u003e\n\u003ctr data-start=\"2482\" data-end=\"2519\"\u003e\n\u003cth data-start=\"2482\" data-end=\"2498\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2498\" data-end=\"2519\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eC8 Desktop Series\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2590\" data-end=\"3082\"\u003e\n\u003ctr data-start=\"2590\" data-end=\"2635\"\u003e\n\u003ctd data-start=\"2590\" data-end=\"2610\" data-col-size=\"sm\"\u003eAirflow Direction\u003c\/td\u003e\n\u003ctd data-start=\"2610\" data-end=\"2635\" data-col-size=\"sm\"\u003eVertical Laminar Flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2636\" data-end=\"2669\"\u003e\n\u003ctd data-start=\"2636\" data-end=\"2654\" data-col-size=\"sm\"\u003eAir Cleanliness\u003c\/td\u003e\n\u003ctd data-start=\"2654\" data-end=\"2669\" data-col-size=\"sm\"\u003eISO Class 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2670\" data-end=\"2697\"\u003e\n\u003ctd data-start=\"2670\" data-end=\"2690\" data-col-size=\"sm\"\u003eHEPA Filter Grade\u003c\/td\u003e\n\u003ctd data-start=\"2690\" data-end=\"2697\" data-col-size=\"sm\"\u003eH14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2698\" data-end=\"2742\"\u003e\n\u003ctd data-start=\"2698\" data-end=\"2723\" data-col-size=\"sm\"\u003eHEPA Filter Efficiency\u003c\/td\u003e\n\u003ctd data-start=\"2723\" data-end=\"2742\" data-col-size=\"sm\"\u003e99.995% @ 0.3μm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2743\" data-end=\"2792\"\u003e\n\u003ctd data-start=\"2743\" data-end=\"2766\" data-col-size=\"sm\"\u003eAverage Air Velocity\u003c\/td\u003e\n\u003ctd data-start=\"2766\" data-end=\"2792\" data-col-size=\"sm\"\u003eApproximately 0.45 m\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2793\" data-end=\"2834\"\u003e\n\u003ctd data-start=\"2793\" data-end=\"2808\" data-col-size=\"sm\"\u003eWork Surface\u003c\/td\u003e\n\u003ctd data-start=\"2808\" data-end=\"2834\" data-col-size=\"sm\"\u003eSUS304 Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2835\" data-end=\"2877\"\u003e\n\u003ctd data-start=\"2835\" data-end=\"2854\" data-col-size=\"sm\"\u003eCabinet Material\u003c\/td\u003e\n\u003ctd data-start=\"2854\" data-end=\"2877\" data-col-size=\"sm\"\u003ePowder-Coated Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2878\" data-end=\"2909\"\u003e\n\u003ctd data-start=\"2878\" data-end=\"2892\" data-col-size=\"sm\"\u003eSide Panels\u003c\/td\u003e\n\u003ctd data-start=\"2892\" data-end=\"2909\" data-col-size=\"sm\"\u003eClear Acrylic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2910\" data-end=\"2939\"\u003e\n\u003ctd data-start=\"2910\" data-end=\"2921\" data-col-size=\"sm\"\u003eLighting\u003c\/td\u003e\n\u003ctd data-start=\"2921\" data-end=\"2939\" data-col-size=\"sm\"\u003eIntegrated LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2940\" data-end=\"2968\"\u003e\n\u003ctd data-start=\"2940\" data-end=\"2949\" data-col-size=\"sm\"\u003eBlower\u003c\/td\u003e\n\u003ctd data-start=\"2949\" data-end=\"2968\" data-col-size=\"sm\"\u003eCentrifugal Fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2969\" data-end=\"2994\"\u003e\n\u003ctd data-start=\"2969\" data-end=\"2982\" data-col-size=\"sm\"\u003ePre-Filter\u003c\/td\u003e\n\u003ctd data-start=\"2982\" data-end=\"2994\" data-col-size=\"sm\"\u003eWashable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2995\" data-end=\"3019\"\u003e\n\u003ctd data-start=\"2995\" data-end=\"3009\" data-col-size=\"sm\"\u003eNoise Level\u003c\/td\u003e\n\u003ctd data-start=\"3009\" data-end=\"3019\" data-col-size=\"sm\"\u003e≤65 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3020\" data-end=\"3050\"\u003e\n\u003ctd data-start=\"3020\" data-end=\"3035\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"3035\" data-end=\"3050\" data-col-size=\"sm\"\u003e220–240V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3051\" data-end=\"3082\"\u003e\n\u003ctd data-start=\"3051\" data-end=\"3075\" data-col-size=\"sm\"\u003eAustralian Compatible\u003c\/td\u003e\n\u003ctd data-start=\"3075\" data-end=\"3082\" data-col-size=\"sm\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"3084\" data-end=\"3087\"\u003e\n\u003ch1 data-section-id=\"2y2wp6\" data-start=\"3089\" data-end=\"3107\"\u003eModel Dimensions\u003c\/h1\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3109\" data-end=\"3288\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3109\" data-end=\"3134\"\u003e\n\u003ctr data-start=\"3109\" data-end=\"3134\"\u003e\n\u003cth data-start=\"3109\" data-end=\"3117\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eModel\u003c\/th\u003e\n\u003cth data-start=\"3117\" data-end=\"3134\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eWorking Width\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3170\" data-end=\"3288\"\u003e\n\u003ctr data-start=\"3170\" data-end=\"3192\"\u003e\n\u003ctd data-start=\"3170\" data-end=\"3183\" data-col-size=\"sm\"\u003eC8-BT-W500\u003c\/td\u003e\n\u003ctd data-start=\"3183\" data-end=\"3192\" data-col-size=\"sm\"\u003e500mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3193\" data-end=\"3215\"\u003e\n\u003ctd data-start=\"3193\" data-end=\"3206\" data-col-size=\"sm\"\u003eC8-BT-W650\u003c\/td\u003e\n\u003ctd data-start=\"3206\" data-end=\"3215\" data-col-size=\"sm\"\u003e650mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3216\" data-end=\"3238\"\u003e\n\u003ctd data-start=\"3216\" data-end=\"3229\" data-col-size=\"sm\"\u003eC8-BT-W800\u003c\/td\u003e\n\u003ctd data-start=\"3229\" data-end=\"3238\" data-col-size=\"sm\"\u003e800mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3239\" data-end=\"3263\"\u003e\n\u003ctd data-start=\"3239\" data-end=\"3253\" data-col-size=\"sm\"\u003eC8-BT-W1000\u003c\/td\u003e\n\u003ctd data-start=\"3253\" data-end=\"3263\" data-col-size=\"sm\"\u003e1000mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3264\" data-end=\"3288\"\u003e\n\u003ctd data-start=\"3264\" data-end=\"3278\" data-col-size=\"sm\"\u003eC8-BT-W1200\u003c\/td\u003e\n\u003ctd data-start=\"3278\" data-end=\"3288\" data-col-size=\"sm\"\u003e1200mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"3290\" data-end=\"3293\"\u003e\n\u003ch1 data-section-id=\"ese5zk\" data-start=\"3295\" data-end=\"3322\"\u003eStandards \u0026amp; Certification\u003c\/h1\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3324\" data-end=\"3502\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3324\" data-end=\"3345\"\u003e\n\u003ctr data-start=\"3324\" data-end=\"3345\"\u003e\n\u003cth data-start=\"3324\" data-end=\"3335\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eStandard\u003c\/th\u003e\n\u003cth data-start=\"3335\" data-end=\"3345\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eStatus\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3394\" data-end=\"3502\"\u003e\n\u003ctr data-start=\"3394\" data-end=\"3423\"\u003e\n\u003ctd data-start=\"3394\" data-end=\"3409\" data-col-size=\"sm\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd data-start=\"3409\" data-end=\"3423\" data-col-size=\"sm\"\u003eScienFocus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3424\" data-end=\"3457\"\u003e\n\u003ctd data-start=\"3424\" data-end=\"3442\" data-col-size=\"sm\"\u003eAir Cleanliness\u003c\/td\u003e\n\u003ctd data-start=\"3442\" data-end=\"3457\" data-col-size=\"sm\"\u003eISO Class 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3458\" data-end=\"3479\"\u003e\n\u003ctd data-start=\"3458\" data-end=\"3472\" data-col-size=\"sm\"\u003eHEPA Filter\u003c\/td\u003e\n\u003ctd data-start=\"3472\" data-end=\"3479\" data-col-size=\"sm\"\u003eH14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3480\" data-end=\"3502\"\u003e\n\u003ctd data-start=\"3480\" data-end=\"3495\" data-col-size=\"sm\"\u003eCE Certified\u003c\/td\u003e\n\u003ctd data-start=\"3495\" data-end=\"3502\" data-col-size=\"sm\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"3504\" data-end=\"3507\"\u003e\n\u003ch1 data-section-id=\"1jxbixs\" data-start=\"3509\" data-end=\"3526\"\u003eWhat's Included\u003c\/h1\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3528\" data-end=\"3717\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3528\" data-end=\"3540\"\u003e\n\u003ctr data-start=\"3528\" data-end=\"3540\"\u003e\n\u003cth data-start=\"3528\" data-end=\"3540\" data-col-size=\"md\" class=\"last:pe-10\"\u003eIncluded\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3555\" data-end=\"3717\"\u003e\n\u003ctr data-start=\"3555\" data-end=\"3610\"\u003e\n\u003ctd data-start=\"3555\" data-end=\"3610\" data-col-size=\"md\"\u003eScienFocus C8 Desktop Vertical Laminar Flow Cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3611\" data-end=\"3630\"\u003e\n\u003ctd data-start=\"3611\" data-end=\"3630\" data-col-size=\"md\"\u003eH14 HEPA Filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3631\" data-end=\"3654\"\u003e\n\u003ctd data-start=\"3631\" data-end=\"3654\" data-col-size=\"md\"\u003eWashable Pre-Filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3655\" data-end=\"3677\"\u003e\n\u003ctd data-start=\"3655\" data-end=\"3677\" data-col-size=\"md\"\u003eCentrifugal Blower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3678\" data-end=\"3701\"\u003e\n\u003ctd data-start=\"3678\" data-end=\"3701\" data-col-size=\"md\"\u003eLED Lighting System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3702\" data-end=\"3717\"\u003e\n\u003ctd data-start=\"3702\" data-end=\"3717\" data-col-size=\"md\"\u003eUser Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"3719\" data-end=\"3722\"\u003e\n\u003ch1 data-section-id=\"yknlu6\" data-start=\"3724\" data-end=\"3746\"\u003eOptional Accessories\u003c\/h1\u003e\n\u003cul data-start=\"3748\" data-end=\"3850\"\u003e\n\u003cli data-section-id=\"5k553b\" data-start=\"3748\" data-end=\"3777\"\u003eReplacement H14 HEPA Filter\u003c\/li\u003e\n\u003cli data-section-id=\"1q8danw\" data-start=\"3778\" data-end=\"3802\"\u003eReplacement Pre-Filter\u003c\/li\u003e\n\u003cli data-section-id=\"hvmuqf\" data-start=\"3803\" data-end=\"3823\"\u003eReplacement Blower\u003c\/li\u003e\n\u003cli data-section-id=\"1r0bbet\" data-start=\"3824\" data-end=\"3850\"\u003eReplacement LED Lighting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3852\" data-end=\"3855\"\u003e\n\u003ch1 data-section-id=\"1jol37q\" data-start=\"3857\" data-end=\"3878\"\u003eWarranty \u0026amp; Shipping\u003c\/h1\u003e\n\u003cp data-start=\"3880\" data-end=\"3916\"\u003e\u003cstrong data-start=\"3880\" data-end=\"3916\"\u003e12-Month Manufacturer's Warranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"3918\" data-end=\"4041\"\u003eAustralian customer support is provided for all ScienFocus laminar flow cabinets supplied by Australian Mycology Equipment.\u003c\/p\u003e\n\u003ch2 data-section-id=\"eibc6t\" data-start=\"4043\" data-end=\"4074\"\u003eFREE Australia-Wide Shipping\u003c\/h2\u003e\n\u003cp data-start=\"4076\" data-end=\"4215\"\u003eFREE shipping is included to most Australian metro and regional locations, generally within \u003cstrong data-start=\"4168\" data-end=\"4214\"\u003e250 km of Australia's major capital cities except Dawin and Hobart\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4217\" data-end=\"4360\"\u003eThese cabinets are imported to order and have an \u003cstrong data-start=\"4266\" data-end=\"4321\"\u003eestimated delivery time of approximately 35–40 days\u003c\/strong\u003e from the date your order is confirmed.\u003c\/p\u003e\n\u003cp data-start=\"4362\" data-end=\"4622\"\u003eIf your delivery address falls outside our standard free shipping area, including remote, rural or difficult-to-access locations, we will contact you with a freight quotation before dispatch. No additional freight charges will be applied without your approval.\u003c\/p\u003e\n\u003chr data-start=\"4624\" data-end=\"4627\"\u003e\n\u003ch1 data-section-id=\"1vv921k\" data-start=\"4629\" data-end=\"4642\"\u003ePlease Note\u003c\/h1\u003e\n\u003cp data-start=\"4644\" data-end=\"4962\"\u003eThe \u003cstrong data-start=\"4648\" data-end=\"4680\"\u003eScienFocus C8 Desktop Series\u003c\/strong\u003e provides a continuous stream of HEPA-filtered air vertically over the work surface, creating an ISO Class 5 clean working environment for contamination-sensitive procedures including agar work, tissue culture, microbiology, grain spawn preparation and laboratory media preparation.\u003c\/p\u003e\n\u003cp data-start=\"4964\" data-end=\"5330\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eVertical laminar flow cabinets are designed to \u003cstrong data-start=\"5011\" data-end=\"5039\"\u003eprotect the work product\u003c\/strong\u003e by directing HEPA-filtered air downward over the workspace. They are \u003cstrong data-start=\"5109\" data-end=\"5143\"\u003enot biological safety cabinets\u003c\/strong\u003e and are \u003cstrong data-start=\"5152\" data-end=\"5250\"\u003enot intended for handling hazardous biological agents, infectious materials or toxic chemicals\u003c\/strong\u003e. Use only for clean laboratory procedures where product protection is required.\u003c\/p\u003e","brand":"Australian Mycology Equipment","offers":[{"title":"C8-BT-W500 Desktop","offer_id":51967965102368,"sku":null,"price":995.0,"currency_code":"AUD","in_stock":true},{"title":"C8-BT-W650 Desktop","offer_id":51967965135136,"sku":null,"price":1145.0,"currency_code":"AUD","in_stock":true},{"title":"C8-PD-W650 Free Standing","offer_id":51967965167904,"sku":null,"price":1395.0,"currency_code":"AUD","in_stock":true},{"title":"C8-BT-W800 Desktop","offer_id":51967965200672,"sku":null,"price":1295.0,"currency_code":"AUD","in_stock":true},{"title":"C8-PD-W800 Free Standing","offer_id":51967965233440,"sku":null,"price":1545.0,"currency_code":"AUD","in_stock":true},{"title":"C8-BT-W1000 Desktop","offer_id":51967965266208,"sku":null,"price":995.0,"currency_code":"AUD","in_stock":true},{"title":"C8-PD-W1000 Free Standing","offer_id":51967965298976,"sku":null,"price":1395.0,"currency_code":"AUD","in_stock":true},{"title":"C8-BT-W1200 Desktop","offer_id":51967965331744,"sku":null,"price":1695.0,"currency_code":"AUD","in_stock":true},{"title":"C8-PD-W1200","offer_id":51967965364512,"sku":null,"price":1995.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0806\/0721\/5904\/files\/Vertica1l.jpg?v=1783698234"}],"url":"https:\/\/australianmycologyequipment.com.au\/collections\/featured-products.oembed","provider":"Australian Mycology Equipment","version":"1.0","type":"link"}